00197551-01_MM_CPP-CP-Twin_Kunde_en - 第42页

Maintenance Tasks for C&P20/A/M/P Head Preparatory Steps 42 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin Multipette ► Prepare the multipette. For more information abo ut this, read s ection "9…

100%1 / 92
Maintenance Tasks for C&P20/A/M/P Head
Preparatory Steps
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 41
4.4
4.4 Preparatory Steps
Preparatory Steps
Preparing the Head Mount
Preparing the Head Mount
Assemble the head mount. For details, refer to the assembly instructions "Universal placement head
mounting rack" [DE+EN: 00196371-xx].
Vacuum test
Set the nozzles for the current nozzle configuration down in the nozzle changer.
Before you begin maintenance work, perform a vacuum test. Use the calibration nozzles for this
(C&P20/A/M: 1235, C&P20 P: 4235).
If vacuum value irregularities occur at certain segments, take a closer look at these during mainte-
nance work. Note down the numbers of the problematic segments for later reference.
Preparing the Placement Head
Dismantle the placement head and remove it from the placement machine. For details, refer to the
service manual for your machine.
Use the FHE function if possible.
Fit the placement head onto the head mount.
Multipette
CAUTION
ESD
Connect the assembly mount ESD connection to an ESD connection at the workplace.
Always observe the ESD regulations described in the user manual.
Protective hose for component sensor (example of
C&P20 A shown)
Fit the protective hose (1) onto the component sen-
sor.
NOTICE!
A cover is used on the C&P20 P, instead of the protective
hose.
Maintenance Tasks for C&P20/A/M/P Head
Preparatory Steps
42 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
Multipette
Prepare the multipette. For more information about this, read section "9 Handling the Multipette"
[ 89]. Also observe the following instructions:
Color-coding of dosage devices and lubricants
CAUTION
Do not combine lubricants!
Contamination (combination) of lubricants can affect the service life of the bearings!
Only use the combitip specifically marked for each lubricant, to avoid combining the lubri-
cants.
Color Tools and lubricants Application
White White combitip
Nye Synthetic Oil 200A 30 ml
Driver bearing
(C&P20 only)
Black Black combitip
Klüberalfa DH 3-100
Driver bearing
(C&P20A/M/P only, not C&P20)
Blue Blue combitip
Lubcon Thermoplex ALN 1001/00 50 ml
Segment guide rail/Z axis guide
(all C&P20 variants)
Maintenance Tasks for C&P20/A/M/P Head
Overview of Lubrication Points
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 43
4.5
4.5 Overview of Lubrication Points
Overview of Lubrication Points
Z linear guide
2 x 4 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove
DP segment guide
2 x 2 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove at each segment
Driver bearing
C&P20:
1 x 1 µl Nye Synthetic Oil 200A (white combitip) per driver
bearing
C&P20A/M/P:
1x 1 µl Klüberalfa DH 3-100 (black combitip) per driver
bearing.