Maintenance Tasks for Pressure Control Valve
Performing Maintenance Tasks 6.3.1 Checking/Cleaning the Pressure Control Valve
72 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
Cleaning the Valve Sensor
Assembling the valve
Insert the plunger into the basic body of the valve.
The anti-twist lock (2) must engage in the groove (1).
Check:
The plunger must move back and forth without effort.
Try to turn the plunger. If it can be turned, the anti-
twist lock has not yet engaged with the groove.
Make sure that the transparent plastic sheet is posi-
tioned correctly on the basic body of the valve.
Cleaning the valve sensor
CAUTION!
The valve sensor can be irreparably damaged by com-
pressed air.
NEVER blow air directly into the vacuum sensor.
Blow the compressed air over the vacuum sensor
tube, as shown in the diagram (1).
⇨ The venturi effect created sucks dirt out of the
tube.
Clean the vacuum sensor with a cleaning stick.
O-ring on vacuum sensor
Slightly grease the O-ring (1) with Isoflex Topas 5051
and position the O-ring onto the vacuum sensor.
Maintenance Tasks for Pressure Control Valve
6.3.1 Checking/Cleaning the Pressure Control Valve Performing Maintenance Tasks
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 73
Assembling the Pressure Control Valve
O-ring on the coil
Lightly grease the O-ring (1) on the coil with Isoflex
Topas 5051.
Wipe off any excess grease.
Fitting the short board
Plug the board and coil (2) into the valve body (1).
CAUTION!
Make sure that the coil is pushed straight into the valve
body.
Do not distort the coil.
Only apply slight pressure.
Fastening the short board
Fix the short board (2) into place, using the three fas-
tening screws (1).
Tighten the fastening screws with a torque of 0.2 Nm.
CAUTION!
The fastening screws for the boards are self-tapping
screws.
Make sure that no new thread is created when screwing
in the screws.
Turn the screws first to the left, in order to use the start of
the existing thread.
Maintenance Tasks for Pressure Control Valve
Performing Maintenance Tasks 6.3.1 Checking/Cleaning the Pressure Control Valve
74 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
Fit the cover plate into place with the three fastening screws. Tighten the fastening screws with a
torque of 0.2 Nm.
Fitting the board board
Position the two white plastic spacers onto the body
of the valve.
Make sure that the sensor (3) slides smoothly into the
opening (2) in the housing.
Fastening the long board
Fix the long board (2) into place with the two fasten-
ing screws (1). Tighten the fastening screws with a
torque of 0.2 Nm.
CAUTION!
The fastening screws for the boards are self-tapping
screws.
Make sure that no new thread is created when screwing
in the screws.
Turn the screws first to the left, in order to use the start of
the existing thread.