Maintenance Tasks for Holding Circuit
7.3.2 C&P20/A/M/P: Cleaning/Checking the Holding Circuit Performing Maintenance Tasks
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 79
Blow through the holding circuit with compressed air.
Keep a distance of at least 1 cm to the holding circuit.
Make sure that the fluid is removed completely from the venturi nozzles.
Start with eh outer holes.
Take care of the index pin.
Rinse the holding circuit with distilled water.
To do this, fill the orange combitip with distilled water
and rinse each of the venturi nozzles from both sides.
Maintenance Tasks for Holding Circuit
Performing Maintenance Tasks 7.3.2 C&P20/A/M/P: Cleaning/Checking the Holding Circuit
80 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
Maintenance Tasks for Nozzles
Maintenance Intervals
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 81
8
8 Maintenance Tasks for Nozzles
Maintenance Tasks for Nozzles
8.1
8.1 Maintenance Intervals
Maintenance Intervals
3000 - Minor - Nozzles
8.2
8.2 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
NOTICE
Example
The following tasks are described using the example of a CPP nozzle magazine. The procedure
is the same for other nozzle magazines. Any relevant differences will be mentioned explicitly.
Make sure that you use the correct cleaning boxes for your nozzles.
Maintenance tasks
Nozzles
Duration
[min]
Each
week
Every 3
months
Every 6
months
Every 12
months
Cleaning/Replacing the Ceramic Nozzles 2 X
Replacing the Plastic Nozzles 2 X
Consumables Item no. HMK
SIPLACE recommends that you use the following cleaning fluids from
ZESTRON (http://www.zestron.com):
VIGON SC 200
Compressed air
Distilled water
Tools Item no. HMK
ESD wriststrap 00320279- xx
SIPLACE recommends that you use the following ultrasound device and
accessory parts from BANDELIN electronic (http://www.bandelin.com):
Ultrasound device SONOREX SUPER RK 510 [order no. Bandelin:
327]
Clip-on basket K 10 [order no. Bandelin: 359]
Handle adjustment GV 10 for baskets (1 pair) [order no. Bandelin: 092]
Lid D 510 [order no. Bandelin: 3008]
Nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
Ceramic nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
If required, nozzle magazine type 40xx (for C&P20 P)
(Replaces: magazine assembly C&P20 [03016831-xx])
03101503- xx
If required, nozzle magazine type 20xx (depending on configuration) 03066107- xx
Plastic brush Dm 8 00325866- xx
For C&P20/A/M/P and CPP
Guiding plate long for 10xx/20xx
Note: When using ceramic nozzles for the CPP, you need the guide
plate with function state 02.
03066508- xx
Cleaning box for ceramic nozzles, type 20xx/long (for CPP) 03076627- xx
Cleaning box ceramic nozzles type 10xx/long (for C&P20/A/M) 03055736- xx