Vision XP+ VAC Page 119
3 Setup Instructions
3.19 Monitoring the Water Flow Rate
Operating Instructions
Version 1.5
3.19 Monitoring the Water Flow Rate
The water connections are located at the front of the system underneath the
cooling zone.
The following conditions must be fulfilled in order to be able to monitor the
water flow rate:
• The system and the conveyor drive unit must be switched on.
• All emergency-off switches have to be unlocked in order that the water cir-
cuit has its flow again.
• The external water circuit must be connected.
Fig. 3-30 Water Flow Rate
A)Flow rate indicator for the
external water circuit
The white marking at the
indicator must lie within the
maximum range of 8.
A

Page 120 Vision XP+ VAC
3 Setup Instructions
3.20 Regulating the Coolant Water Circuit
Operating Instructions
Version 1.5
3.20 Regulating the Coolant Water Circuit
+
Fig. 3-31 Coolant Water Regulation
A)Coolant water regulator
The temperature of the coolant
water is regulated here.
The water flow rate is increased if
temperature needs to be
reduced, and the water flow rate
is reduced if temperature needs
to be increased.
B) Pressure controller
This controller checks the water
flow and triggers the alarm „water
pressure too low“ (if necessary).
A
B

Vision XP+ VAC Page 121
3 Setup Instructions
3.21 Checking and Adjusting Nitrogen Pressure
Operating Instructions
Version 1.5
3.21 Checking and Adjusting Nitrogen Pressure
The compressed air and nitrogen unit is located at the front of the system
underneath the last cooling zone.
Fig. 3-32 Compressed Air and Nitrogen Unit
A) Pressure sensor
B) Nitrogen control
C) Isolation purge valve (pressure meter)
D) Flow meter / Pyrolysis with monitoring for venturi tube
E) Nitrogen switching (motor actuator)
F) Pressure gauge (behind the motor actuator)
G) Compressed air switching (motor actuator)
H) Nitrogen feed to process chamber (flow meter)
I) N2/O2 switch over valve
J) Purge valve process chamber
K) N2 usage indicator
F
A
E
H
G
K
D
J
C
B
I