Page 128 Vision XP+ V AC 3 Setup Instructions 3.22 Default V alues Operating Instructions V ersion 1.5 3.22.5 Interface Default V alues T ab . 3-9 Inter face (defau lt values) 3.22.6 Conveyor Default V alues • „ Rel +/-“…

Vision XP+ VAC Page 127
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.4 Fans Monitoring Default Values
Fig. 3-33 Fans Parameter (example)
Tab. 3-8 Fans Monitoring (default values)
They are mounted optionally as 7 frequency converters, the numbers of fre-
quency converters have to be allocated to the appropriate system areas.
Fans Position
Entry Frequency Converter No.
Preheating on top (zone 1-8) 1
Preheating down (zone 1-8) 2
Peak on top (Peak zone 1-3) 3
Peak down (Peak zone 1-3) 4
Cooling Zone 1 5
Cooling Zone on top (Cooling Zone 2-4) 6

Page 128 Vision XP+ VAC
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.5 Interface Default Values
Tab. 3-9 Interface (default values)
3.22.6 Conveyor Default Values
• „Rel +/-“ 0,04 in for the PCB-width, CBS-position1 and 2
• „Rel +“ 0,4 in and „Rel -“ 0,4 in, „Ymax“ 100 % for the speed
• Operating state is MANUELL
Type
Entry Field Value
Interface Lane 1 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses
Interface Lane 2 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses

Vision XP+ VAC Page 129
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.7 Conveyor Drive Parameter Default Values
Tab. 3-10 Conveyor Drive Parameter (default values)
3.22.8 Chain Lubricator Default Values
Tab. 3-11 Chain Lubricator (default values)
Type
Definition Software
Lane 1
Speed
Pulses 100
in / mm 26,6 / 675
Max 2300
Filter 10
CCS 10
Offset Min -500
Offset Max 500
Lane 2
Speed
Pulses 100
in / mm 26,6 / 675
Max 2300
Filter 10
CCS 10
Offset Min -500
Offset Max 500
Type
Entry Field Value VAC
Conveyor Duration set value 150 Pulses 150 Pulses
Pause set value 10000 Pulses 10000 Pulses
Impulse duration 4 s 4 s
Impulse pause 60 Pulses 60 Pulses
Center Support
(option)
Duration set value 150 Pulses 150 Pulses
Pause set value 10000 Pulses 10000 Pulses
Impulse duration 4 s 4 s
Impulse pause 60 Pulses 60 Pulses
Outlet 300000 Pulses