ServiceInstruction_Vision XP - 第40页
Page 36 Vision XP+ V AC 2 M aintenance 2.8 V acu um Unit Operating Instructions V ersion 1.5 2.8.6 Back of plant below the vacuum chamber Fig. 2-5 1 Back o f plant be low the va cuum ch amber 1. Oil the spindles, then op…

Vision XP+ VAC Page 35
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.5 Single track vacuum chamber settings
Fig. 2-50 Single track vacuum chamber settings
Detailed adjustment data for single track vacuum chambers

Page 36 Vision XP+ VAC
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.6 Back of plant below the vacuum chamber
Fig. 2-51 Back of plant below the vacuum chamber
1. Oil the spindles, then open and close vacuum chamber several times.
2. Chain tension (1 cm)
1
2
1
1
2

Vision XP+ VAC Page 37
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.7 Check the chain slack
Fig. 2-52 Check the chain slack
Slack in the transport chain in the
vacuum chamber must be checked
from time to time.
The chain should have no more
than 4 cm slack.
The chain can be adjusted using the
chain tensioner.