Page 40 Vision XP+ V AC 2 M aintenance 2.8 V acu um Unit Operating Instructions V ersion 1.5 2.8.10 V acuum pump filter Fig. 2-5 7 Filter V acuum pump Fig. 2-5 8 Filter V acuum pump Fig. 2-5 9 Filter V acuum pump The fil…

100%1 / 142
Vision XP+ VAC Page 39
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.9 Optical fibre sensors before and after the vacuum chamber
Fig. 2-55 Optical fibre sensors at the vacuum
chamber
Fig. 2-56 Optical fibre sensors at the vacuum
chamber
Optical fibre sensors are located be-
fore and after the vacuum chamber.
These optical fibre sensors are used
for PC board identification.
The specified as-is value of these
sensors is 4 000 digits (shown in
red).
Rehm Thermal Systems techni-
cians preset the switching threshold
to 2 700 digits (shown in yellow).
The PC board will be detected when
the threshold level is exceeded.
The contamination level is given as
a percentage. An alarm will in addi-
tion be triggered in the display
should this approach the threshold
level.
To continue proper operation, the
sensor should then be cleaned as
soon as possible, using an appropri-
ate cleaning agent.
The settings are based on Rehm
Thermal Systems experience.
Page 40 Vision XP+ VAC
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.10 Vacuum pump filter
Fig. 2-57 Filter Vacuum pump
Fig. 2-58 Filter Vacuum pump
Fig. 2-59 Filter Vacuum pump
The filter container in front of the
vacuum pump must be opened from
time to time and the filter cleaned.
Consumbales, tool:
Cleaning agent
Cleaning cloth
Cleaning bath
Procedure
1. The clamping ring of the filter
container must be opened.
The lid can be removed.
2. If the paper filter is dirty, it
must be replaced.
3. Lay the fabric filters in a suit-
able cleaning agent for clean-
ing.
4. After cleaning, put everything
back together and close the
clamping ring of the filter con-
tainer.
Vision XP+ VAC Page 41
2 Maintenance
2.8 Vacuum Unit
Operating Instructions
Version 1.5
2.8.11 Check the fill level of the vacuum pump and top up
(The pump is operated with PFPE liquid)
Fig. 2-60 vakuum pump
Procedure:
1. Remove the panel on the sys-
tem.
2. Switch off the pump.
3. Check the fill level at the inspec-
tion window (A). The level indi-
cators min. and max. are
located on the right next to the
inspection window (B).
4. If the fill level is at the min.
mark, top up the medium.
5. With a spanner, remove the lid
(C).
6. Pour in the medium using a fun-
nel up to approx. midway be-
tween the min. and max. marks.
7. Refit the lid.
A
B
C
Attention!
The vacuum pump is operated with PFPE liquid.
Be sure to also note the information provided by the vacuum pump manu-
facturer. The manufacturer's instructions are stored in the folder "Compo-
nent documentation".