ERR-LIST-ACM - 第14页
621 %1 :\tPosition warning 622 %1 :\tSettling time overflow 623 %1 :\tMeasurement pre-alarm 624 %1 :\tAlignment error An axis was unable to perform the magnetic alignment. See Service Manual See Service Manual 625 %1 :\t…

583
Transport :\tTimeout on activating
mechanical stopper
The actual movement of the
stopper is checked by a sensor.
The sensor didn't signal the
requested movement in time.
- The stopper moves too slow because of excessive friction
- The pressure of the compressed air is too low or completely
absent
- The compressed air valve or its control signal is
malfunctioning
- The sensor which detects the position is malfunctioning
- If the stopper doesn't move at all:
Check the compressed air, the valve and the wiring to the valve
- If the stopper moves
Check the sensor and its wiring
- Exchange the stopper
584
Transport :\tTimeout on
deactivating mechanical stopper
The actual movement of the
stopper is checked by a sensor.
The sensor didn't signal the
requested movement in time
- The stopper moves too slow because of excessive friction
- The pressure of the compressed air is too low or completely
absent
- The compressed air valve or its control signal is
malfunctioning
- The sensor which detects the position is malfunctioning
- If the stopper doesn't move at all:
Check the compressed air, the valve and the wiring to the valve
- If the stopper moves
Check the sensor and its wiring
- Exchange the stopper
600 %1 :\tFirst tracking warning Z Tracking warning Z Mechanical friction too high Lubricate Z Motor Rack and Gear as described in the Service Manual
601
%1 :\tFirst tracking warning phi
Tracking warning PHI
Mechanical friction too high
See Service Manual
602 %1 :\tTracking warning Z Tracking warning Z Mechanical friction too high Lubricate Z Motor Rack and Gear as described in the Service Manual
603
%1 :\tTracking warning phi
Tracking warning PHI
Mechanical friction too high
See Service Manual
610 %1 :\tNo message
During communication an error
has been signalized.
611 %1 :\tTracking warning lift
Lift position deviation larger than
allowed in position warning
window.
- Mechanical friction too high.
- Warning window too small.
612 %1 :\tTracking warning puller
Puller position deviation larger
than allowed in position warning
window.
- Mechanical friction too high.
- Warning window too small.
613 %1 :\tTracking warning snap-in
Snap-in position deviation larger
than allowed in position warning
window.
- Mechanical friction too high.
- Warning window too small.
614 %1 :\tSafety door open Trolley safety door is open.
-Trolley door is opened (during production).
- Power failure on piggyback board controller (during
initialization).
- Close door !!!!
- Check fuse on piggyback board, if broken replace it. If the problem still exits,
contact your service representative.
615 %1 :\tStorage error carrier (front)
The laser beam at the front side of
the trolley is obstructed.
- One of the carriers is not in the correct position.
- The adjustment of the laser beam is not correct.
- Check if all carriers are in the correct position.
- If that problem still exists, contact your service representative.
616
%1 :\tChannel run out of
components - Refill feeder channel.
617
%1 :\tEmpty pocket detected
- Continue.
618
Feeder Section %1 :\tFeeder %2,
Channel %3 is almost empty
Feeder
section is
almost empty
The selected feeder carrier is
almost empty. - After eject, refill the carrier.
619 %1 :\tFirmware restart
Communication error has been
occurred (bitbus error).
620
%1 :\tIndex checking
Index checking.

621
%1 :\tPosition warning
622
%1 :\tSettling time overflow
623
%1 :\tMeasurement pre-alarm
624 %1 :\tAlignment error
An axis was unable to perform the
magnetic alignment. See Service Manual See Service Manual
625
%1 :\tSequence error occurred
626 %1 :\tExternal position warning
Inputs for the controller units not
correct. See Service Manual See Service Manual
627
%1 :\tNot most recent LIMMS
firmware loaded in axis
controller(s)
Not most recent LIMMS firmware
loaded in axis controller(s). - A newer firmware version exists. - Download newest LIMMS firmware version.
628 H-drive lubrication requested
The H-Drive of the machine needs
to be lubricated. - Preventive maintenance.
- See the maintenance instructions XY in the service manual for lubrication of
the XY-system.
630 %1 :\tAuto retry on pick
After the pick action no component
is detected. An auto retry is
executed.
- Bad feeder.
- Not calibrated feeder position.
- Check feeder pick-up position.
- Re-calibrate feeder section.
631 %1 :\tRetry on FA action.
The fiducial alignment action
failed, an auto retry is executed. - Bad fiducial or bad fiducial description. - Check fiducial by SETUP-VISION.
632
%1 :\tvacuum level open nozzle
too low
When calibrating the open vacuum
level of a head, the measured
value is within the warning area.
- Dirty toolbit in head.
- Dirty vacuum system.
- Check if the toolbit is dirty.
- Check vacuum system.
633
%1 :\tvacuum level closed nozzle
too high
When calibrating the closed
vacuum level of a head, the
measured value is within the
warning area. - Nozzle vacuum leakage.
- Check if the toolbit is correct connected.
- Check vacuum system.
634 %1 :\tAuto retry on CA action
The component alignment action
failed, a auto retry is executed. - Bad component or bad component description.
- If this happens regularly check component and component data by SETUP-
VISION.
635 %1 :\tPick X correction exceeded
The pick-corrections exceeds the
limits. - Walking feeder. - Fix feeder and re-calibrate section.
636 %1 :\tPick Y correction exceeded
The pick-corrections exceeds the
limits. - Walking feeder. - Fix feeder and re-calibrate section.
640
%1 :\tZ=0 offset not consistent
with calibrated value
Z=0 offset not consistent with
calibrated value.
- PHI/Z drift in head.
- Controller card read combination not correct. - Re-calibrate.
641
%1 :\tPHI=0 offset not consistent
with calibrated value
PHI=0 offset not consistent with
calibrated value.
- PHI/Z drift in head.
- Controller card read combination not correct.
- Re-calibrate head.
- Exchange head.
642
%1 :\tXY=(0,0) not consistent with
calibrated value
XY=(0,0) not consistent with
calibrated value. - XY-drift in H-drive. - Re-calibrate system.
643
Calibration slide temp tolerance
warning Temperature tolerance warning. - Temperature under 0 Celcius or above 60 Celcius. - If warning occurs frequently, contact your service representative.
644 Calibration slide temp drift warning Temp drift warning - Temperature drift higher then 1 degree Celcius per minute. - Contact your service representative.
645
Y left-right offset not consistent
with calibrated value
Y left-right offset not consistent
with calibrated value. - Y-drift. - Recalibrate.
646 %1 :\tSafety door open Trolley safety door is open.
-Trolley door is opened (during production).
- Power failure on piggyback board controller (during
initialization).
- Close door.
- Check fuse on piggyback board, if broken replace it. If the problem still exists,
contact your service representative.

647 %1 :\tDump full
There is no more space on the
reuse dump to put components
on. - Many components have been dumped on the reuse dump. - Empty the reuse dump unit.
648
Feeder Section %1 :\tRepicks
exceeded, picks from Feeder %2,
channel %3 redirected to alternate
tape feeder
The system is switching to an
alternate feeder.
- Feeder is empty.
- There is an error occurred on feeder.
- Refill feeder.
- Replace feeder.
649
Transport :\ttimeout occurred
during lift calibration
The lift calibration has a time-out;
lift calibration is automatically
initiated by the system when the
transport is started. - The movement class for transport lift calibration is too slow. - Adjust the movement class for transport lift calibration.
650 %1 :\tInvalid force specified
The requested force cannot be
applied with the current toolbit. - Wrong toolbit or wrong force specified. - Change toolbit or change force.
700
Cannot read CA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified CA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
701
Cannot read FA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified FA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
702
Cannot read BM package '%1'
because it is not on machine, or
ftp error
Cannot read the specified BM
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
703
Cannot delete CA package '%1'
because it is still used
Cannot delete CA package
because it is still used. - Order is still in use. - Wait until order is deleted.
704
Cannot delete FA package '%1'
because it is still used
Cannot delete FA package
because it is still used. - Order is still in use. - Wait until order is deleted.
705
Cannot delete BM package '%1'
because it is still used
Cannot delete BM package
because it is still used in action
specifications. - Order is still in use. - Wait until order is deleted.
706 Cannot delete CA package '%1'
Cannot remove CA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
707 Cannot delete FA package '%1'
Cannot remove FA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.