647 %1 :\tDump full There is no more space on the reuse dump to put components on. - Many components have been dumped on the reuse dump. - Empty the reuse dump unit. 648 Feeder Section %1 :\tRepicks exceeded, picks from …

621
%1 :\tPosition warning
622
%1 :\tSettling time overflow
623
%1 :\tMeasurement pre-alarm
624 %1 :\tAlignment error
An axis was unable to perform the
magnetic alignment. See Service Manual See Service Manual
625
%1 :\tSequence error occurred
626 %1 :\tExternal position warning
Inputs for the controller units not
correct. See Service Manual See Service Manual
627
%1 :\tNot most recent LIMMS
firmware loaded in axis
controller(s)
Not most recent LIMMS firmware
loaded in axis controller(s). - A newer firmware version exists. - Download newest LIMMS firmware version.
628 H-drive lubrication requested
The H-Drive of the machine needs
to be lubricated. - Preventive maintenance.
- See the maintenance instructions XY in the service manual for lubrication of
the XY-system.
630 %1 :\tAuto retry on pick
After the pick action no component
is detected. An auto retry is
executed.
- Bad feeder.
- Not calibrated feeder position.
- Check feeder pick-up position.
- Re-calibrate feeder section.
631 %1 :\tRetry on FA action.
The fiducial alignment action
failed, an auto retry is executed. - Bad fiducial or bad fiducial description. - Check fiducial by SETUP-VISION.
632
%1 :\tvacuum level open nozzle
too low
When calibrating the open vacuum
level of a head, the measured
value is within the warning area.
- Dirty toolbit in head.
- Dirty vacuum system.
- Check if the toolbit is dirty.
- Check vacuum system.
633
%1 :\tvacuum level closed nozzle
too high
When calibrating the closed
vacuum level of a head, the
measured value is within the
warning area. - Nozzle vacuum leakage.
- Check if the toolbit is correct connected.
- Check vacuum system.
634 %1 :\tAuto retry on CA action
The component alignment action
failed, a auto retry is executed. - Bad component or bad component description.
- If this happens regularly check component and component data by SETUP-
VISION.
635 %1 :\tPick X correction exceeded
The pick-corrections exceeds the
limits. - Walking feeder. - Fix feeder and re-calibrate section.
636 %1 :\tPick Y correction exceeded
The pick-corrections exceeds the
limits. - Walking feeder. - Fix feeder and re-calibrate section.
640
%1 :\tZ=0 offset not consistent
with calibrated value
Z=0 offset not consistent with
calibrated value.
- PHI/Z drift in head.
- Controller card read combination not correct. - Re-calibrate.
641
%1 :\tPHI=0 offset not consistent
with calibrated value
PHI=0 offset not consistent with
calibrated value.
- PHI/Z drift in head.
- Controller card read combination not correct.
- Re-calibrate head.
- Exchange head.
642
%1 :\tXY=(0,0) not consistent with
calibrated value
XY=(0,0) not consistent with
calibrated value. - XY-drift in H-drive. - Re-calibrate system.
643
Calibration slide temp tolerance
warning Temperature tolerance warning. - Temperature under 0 Celcius or above 60 Celcius. - If warning occurs frequently, contact your service representative.
644 Calibration slide temp drift warning Temp drift warning - Temperature drift higher then 1 degree Celcius per minute. - Contact your service representative.
645
Y left-right offset not consistent
with calibrated value
Y left-right offset not consistent
with calibrated value. - Y-drift. - Recalibrate.
646 %1 :\tSafety door open Trolley safety door is open.
-Trolley door is opened (during production).
- Power failure on piggyback board controller (during
initialization).
- Close door.
- Check fuse on piggyback board, if broken replace it. If the problem still exists,
contact your service representative.

647 %1 :\tDump full
There is no more space on the
reuse dump to put components
on. - Many components have been dumped on the reuse dump. - Empty the reuse dump unit.
648
Feeder Section %1 :\tRepicks
exceeded, picks from Feeder %2,
channel %3 redirected to alternate
tape feeder
The system is switching to an
alternate feeder.
- Feeder is empty.
- There is an error occurred on feeder.
- Refill feeder.
- Replace feeder.
649
Transport :\ttimeout occurred
during lift calibration
The lift calibration has a time-out;
lift calibration is automatically
initiated by the system when the
transport is started. - The movement class for transport lift calibration is too slow. - Adjust the movement class for transport lift calibration.
650 %1 :\tInvalid force specified
The requested force cannot be
applied with the current toolbit. - Wrong toolbit or wrong force specified. - Change toolbit or change force.
700
Cannot read CA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified CA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
701
Cannot read FA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified FA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
702
Cannot read BM package '%1'
because it is not on machine, or
ftp error
Cannot read the specified BM
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
703
Cannot delete CA package '%1'
because it is still used
Cannot delete CA package
because it is still used. - Order is still in use. - Wait until order is deleted.
704
Cannot delete FA package '%1'
because it is still used
Cannot delete FA package
because it is still used. - Order is still in use. - Wait until order is deleted.
705
Cannot delete BM package '%1'
because it is still used
Cannot delete BM package
because it is still used in action
specifications. - Order is still in use. - Wait until order is deleted.
706 Cannot delete CA package '%1'
Cannot remove CA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
707 Cannot delete FA package '%1'
Cannot remove FA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.

708 Cannot delete BM package '%1'
Cannot remove BM package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
709 Cannot read CA package '%1'
Cannot read the specified CA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
710 Cannot read FA package '%1'
Cannot read the specified FA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
711 Cannot read BM package '%1'
Cannot read the specified BM
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
712 Cannot delete CA package '%1'
Cannot delete CA specified
package. - Illegal modification of the package. - Re-install package(s).
713 Cannot delete FA package '%1'
Cannot delete FA specified
package. - Illegal modification of the package. - Re-install package(s).
714 Cannot delete BM package '%1'
Cannot delete Bad mark specified
package. - Illegal modification of the package. - Re-install package(s).
715 Cannot write CA package '%1'
Cannot write the specified CA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
716 Cannot write FA package '%1'
Cannot write the specified FA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
717 Cannot write BM package '%1'
Cannot write the specified BM
package.
- The package is not on the machine
- The package is not in the index file
- There has been an internal communication error
- Install the package on the machine
- Retry the action. If the problem persists, contact your service representative.
718 Cannot measure CA package '%1'
Cannot measure specified CA
package. - See detailed error cause. - Modify description and retry.
719 Cannot measure FA package '%1'
Cannot measure specified FA
package. - See detailed error cause. - Modify description and retry.
720 Cannot measure BM package '%1'
Cannot measure specified BM
package. - See detailed error cause. - Modify description and retry.
721 Cannot draw CA definition Cannot draw the CA definition. - Illegal modification of the package. - Re-install package(s).