ERR-LIST-ACM - 第20页
1305 CA Camera %1 is not defined in the SC configuration file A conflict is detected in the administration configuration files. (System controller and process controller files) - Illegal update of these configuration fil…

1202 No diskette present No diskette is in the drive.
- No diskette in the drive.
- Defective drive.
- Insert diskette in drive.
- Contact your service representative for repairs.
1203 Diskette is write protected
The diskette is protected against
writing. - The write-protect tab is enabled.
- Disable the write-protection switch on the diskette and retry the action. Be
careful! There might be important data on the diskette.
1204
Disk is full during backup of
directory: %1 The diskette is full.
- Too many files were on the diskette before the backup began.
- The data to be backed up is too large.
- Use an empty diskette for the backup, try again.
- There is an abnormal amount of data to be backed up, warn your service
representative.
1205 Can't remove file or directory %1
The file or directory cannot be
removed. - Diskette may be corrupted or unformatted.
- Try to repair the diskette, using 'CHKDSK A:' on an MSDOS PC.
- Format the diskette.
1206 The beeper is disabled The beeper is disabled. - The configuration data disabled the beeper. - Modify configuration file (See manual).
1207 Restore XY data failed
Failed to restore XY data: transfer
of (one of the) data files to the
aPC has failed.
- Connection between SC and aPC not OK.
- One or more of the data files to restore are damaged.
- The diskette was removed before all files were transferred.
- Restart the machine.
- Use valid data files.
- Leave the diskette in the drive until the restore has finished.
1208
Function cannot be executed in
this state
The SC or aPC is not in a state in
which restoring XY calibration data
is allowed. - There are active orders. - Remove the orders.
1209
Unable to set the machine date
and time - A similar command is currently being executed - Wait till the current command is executed and then try again
1300
Dump position %1 is not defined in
the APC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1301
Dump position %1 is not defined in
the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1302
Head %1 is not defined in the SC
configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1303
Head %1 has conflicting types in
SC (%2) and APC (%3)
configuration
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1304
Head %1 is not defined in the APC
configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.

1305
CA Camera %1 is not defined in
the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1306
CA Camera %1 has conflicting
types in SC (%2) and APC (%3)
configuration
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1307
CA Camera %1 is not defined in
the APC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1308
FA Camera %1 is not defined in
the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1309
FA Camera %1 has conflicting
types in SC (%2) and APC (%3)
configuration
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1310
FA Camera %1 is not defined in
the APC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1311
Coplanarity unit is not defined in
the APC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1312
Coplanarity unit is not defined in
the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1315
Hdrive setting mismatch between
SC and APC
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1316
Failed to restore configuration
data, defaults loaded
1317
Failed to restore set-up data,
defaults loaded
1318
Failed to restore action spec data,
defaults loaded
1319
Failed to restore machine data,
defaults loaded
System could not restore machine
data, defaults used instead.
- First startup after new software installation or startup after a
forced shutdown (power-dip). - Check and correct machine data.

1320
Failed to restore board location
data, defaults loaded
- First startup after new software installation or startup after a
forced shutdown (power-dip). - Don't switch to simulation mode before you start the machine.
1321 Failed to retrieve vision data
When starting-up the machine, the
vision-system could not get all
necessary data from the APC.
- One of the vision files is not correct, it may contain bad
characters or missing information. - Locate the bad vision file, and correct it.
1322
Failed to restore timer data,
defaults loaded
1323
Failed to restore error messages
1324
Failed to configure transport
controller
1325
Failed to retrieve toolbit data
1326
Failed to retrieve order data
1327
Unable to set date/time
1329
Toolbit exchange unit %1 is not
defined in the APC configuration
file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files - Re-configure item.
1331
Toolbit exchange unit %1 is not
defined in the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1332
Unable change control state
because existing state is HOST -
OFFLINE.
Existing control state is preventing
the request for new control state to
be sent. Existing control state is host - offline. Wait for for the host to go online and try again.
1400 Refresh calibration requested.
A refresh calibration should be
executed, to assure accuracy. - Possible changes in machine base.
- Execute refresh calibration.
- NOTE: Do not clear this message before completion of the action.
1401 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1402 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1403 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1404 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1500
Process
1501
Machine
1502
Transport
1503
Coplanarity
1504
Head 1
1505
Head 2
1506
Head 3
1507
Head 4
1508
Feeder Section 1
1509
Feeder Section 2
1510
Feeder Section 3
1511
Feeder Section 4