ERR-LIST-ACM - 第22页
1512 Limms-X 1513 Limms-YR 1514 Limms-YL 1515 Limms supplies 1516 H-Drive 1517 SBIP 1518 CA (Front) 1519 CA (Rear) 1520 FA (Front) 1521 FA (Rear) 1522 CA (Front-Left) 1523 CA (Front-Right) 1524 CA (Rear-Right) 1525 CA (R…

1320
Failed to restore board location
data, defaults loaded
- First startup after new software installation or startup after a
forced shutdown (power-dip). - Don't switch to simulation mode before you start the machine.
1321 Failed to retrieve vision data
When starting-up the machine, the
vision-system could not get all
necessary data from the APC.
- One of the vision files is not correct, it may contain bad
characters or missing information. - Locate the bad vision file, and correct it.
1322
Failed to restore timer data,
defaults loaded
1323
Failed to restore error messages
1324
Failed to configure transport
controller
1325
Failed to retrieve toolbit data
1326
Failed to retrieve order data
1327
Unable to set date/time
1329
Toolbit exchange unit %1 is not
defined in the APC configuration
file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files - Re-configure item.
1331
Toolbit exchange unit %1 is not
defined in the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1332
Unable change control state
because existing state is HOST -
OFFLINE.
Existing control state is preventing
the request for new control state to
be sent. Existing control state is host - offline. Wait for for the host to go online and try again.
1400 Refresh calibration requested.
A refresh calibration should be
executed, to assure accuracy. - Possible changes in machine base.
- Execute refresh calibration.
- NOTE: Do not clear this message before completion of the action.
1401 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1402 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1403 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1404 Timer for %1 has expired
The timer for the specified flux
applicator has expired.
- The pot lifetime for specified flux applicator has been
exceeded. - Replace flux.
1500
Process
1501
Machine
1502
Transport
1503
Coplanarity
1504
Head 1
1505
Head 2
1506
Head 3
1507
Head 4
1508
Feeder Section 1
1509
Feeder Section 2
1510
Feeder Section 3
1511
Feeder Section 4

1512
Limms-X
1513
Limms-YR
1514
Limms-YL
1515
Limms supplies
1516
H-Drive
1517
SBIP
1518
CA (Front)
1519
CA (Rear)
1520
FA (Front)
1521
FA (Rear)
1522
CA (Front-Left)
1523
CA (Front-Right)
1524
CA (Rear-Right)
1525
CA (Rear-Left)
1526
Dump 1
1527
Dump 2
1528
Dump 3
1529
Dump 4
1532
Cover (Front)
1533
Cover (Rear)
1534
Cover
1535
Therm. switch
1536
E-Stop (Front)
1537
NOT USED
1538
E-Stop (Rear)
1539
Feeder Section 1
1540
Feeder Section 2
1541
Feeder Section 4
1542
Feeder Section 3
1543
%?
1544
outer
1545
inner
1546
Initializing communication....
1547
Uploading vision files....
1548
Initializing....
1549
%1:Automatic retry on pick error
Only used in MIS reports.
1550
%1:Automatic retry on CA error
(including dump and repick) Only used in MIS reports.
1551
%1 :\tAutomatic retry FA (Spare
measured) Only used in MIS reports.
1552
Flux applicator (Front-Left)
1553
Flux applicator (Front-Right)
1554
Flux applicator (Rear-Right)
1555
Flux applicator (Rear-Left)
1556
RVS
1558
TEU (Rear)
1560
TEU (Front)
1561
Feeder Section 5
1562
Feeder Section 5
1600 SVS :\tUndefined error The SVS error is not defined yet. Unknown.
- Retry and continue.
- Report error to your service representative.
1601 SVS :\tUndefined warning
The SVS warning is not defined
yet. Unknown.
- Retry and continue.
- Report warning to your service representative.

1602
SVS :\tSetup not OK for feeder
%1.%2
SVS detected a mismatch
between current feeder setup and
setup requested by action spec.
A new order with different action spec and feeder setup is
started. Check with SVS system.
1603
SVS :\tCommunication error to
CIMCIS system with feeder
section %1 A system error occurred. Unknown.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
1604
SVS :\tCommunication error with
feeder %1.%2, A system error occurred. Unknown. Check with SVS system.
1650
SVS :\tFeeder %1.%2 (channel
%3) low
The specified feeder is almost
empty. The feeder has not been refilled recently. Refill feeder with components.
2001 %1 :\tPower dip detected
Power dip detected in the servo
power supply circuitry.
- The system power dropped, for a small time period, below a
defined level. - Check system power supply.
2002 %1 :\tZero coarse Z not found
The zero coarse of the Z servo is
not found in a homing action.
- Defective EPD-wiring.
- Defective EPD.
- Defective fuse (F1..4) on main connector board.
- Defective wiring between motor and motor control.
- Defective motor
- Defective motor control
- Check the EPD and EPD-wiring.
- Check the fuse on main connector board.
- Check wiring between motor and motor control.
- Check motor.
- Retry actions, if not correct, then contact your service representative.
2003 %1 :\tZero fine Z not found
The zero fine (encoder marker
pulse) of the Z servo is not found
in a homing action.
- Defective wirling.
- Defective encoder.
- Defective electronics.
- Check wirling.
- Check encoder.
- Check electronics (controller board).
- Retry operation, if not correct then contact your service representative.
2005 %1 :\tAmplifier Z disabled
The amplifier of the Z servo is
disabled. - Software error in aPC. - Retry action, if not correct contact your service representative.
2006 %1 :\tZ not homed The Z servo is not homed. - Software error in aPC. - Retry action, if not correct contact your service representative.
2007 %1 :\tZero drift Z
The Z servo has received too
many or too less encoder pulses
which is interpreted as a shift in
the zero fine position.
- Defective wiring.
- Defective encoder.
- Defective electronics.
- Check wiring.
- Check encoder.
- Check electronics (controller board).
- Retry operation, if not correct then contact your service representative.
2008 %1 :\tPosition error Z
Position deviation in Z larger than
defined in error window.
- Movement outside mechanical range.
- Mechanical friction too high.
- Defective fuse (F1..4) on main connector board.
- Defective wiring.
- Defective motor.
- Defective motor controller.
- Check mechanical friction according to the procedure described in the Service
Manual.
- Check fuse on main connector board.
- Check cables, motor and motor controller.
2009 %1 :\tCommunication time out Z
No response of Z servo controller
within the defined time interval.
- Defective servo controller (LM628) on the placement head
controller. - Replace placement head controller board.