ERR-LIST-ACM - 第39页
3004 %1 :\tFA Front-right Rear-right tolerance The measured distance between the FRONT-RIGHT and the REAR- RIGHT head-marker is out of tolerance. - Not correctly mounted /calibrated marker reference plate. - Not correctl…

2946 %1 :\tFeeder not present - Internal software error. - Report error to your service representative.
2947
%1 :\tTape index failed
Not supported yet.
2948 %1 :\tFeeder was already selected Feeder was already selected. - Possible duplicates in action spec. - Check action spec on duplicates.
2949
%1 :\tSplice detected
Not supported yet.
2950
Feeder Section %1 :\tSplice at
pick-position Not supported yet.
2951
%1 :\tReverse polarity
Not supported yet.
2952 %1 :\tController in wrong state
Feeder controller is in the wrong
state for the execution of
requested command. - Internal software error. - Report error to your service representative.
2953 %1 :\tToo many feeders selected
More than the maximum allowed
number of feeders was selected. - Internal software error. - Report error to your service representative.
2954 %1 :\tIllegal selection
Requested feeder cannot be
selected. - Incorrect action spec. - Adjust action spec.
2955 %1 :\tFeeder not selected
Trying to use feeder section that
has not selected a feeder. - Internal software error. - Report error to your service representative.
2956 %1 :\tFeeder was selected
Action requested cannot be done
for a selected feeder. - Internal software error. - Report error to your service representative.
2957 %1 :\tController is busy
The feeder controller is busy
execution a previous requested
command - Internal software error - Report error to your service representative.
2958
%1 :\tComponent class is out of
range
The specified component class is
out of range. - Internal software error. - Report error to your service representative.
2959
%1 :\tSection returned an
unknown response
The feeder section returned an
unknown response. - Firmware crashed. - Reconfigure trolley.
2960 %1 :\tFeeder section not present
Command sent to non-existing
feeder controller.
- Section was removed and not replaced.
- Configuration is not correct
- Replace feeder section or place safety cover.
- Reconfigure machine.
2961
%1 :\tSection number is out of
range
The section number does not
exist. - Internal software error. - Report error to your service representative.
2962
%1 :\tCommunication with
modules suspended
The communication with several
modules (feeder section, transport
and heads) is suspended by the
"Prepare trolley exchange" action.
- Prepare trolley exchange has been executed and the trolley
has not yet been replaced. - Replace trolley or place safety covers.
3000 %1 :\tCalibration error
Calibration is not successfully
finished, because of a machine
error.
- Vision, toolbit, head, or other module have occurred machine
errors. - Verify mechanical adjustment of module.
3001 %1 :\tNo Calibration nozzle
The calibration nozzle, needed to
calibrate, is not mounted on head.
- Calibration nozzle not mounted.
- Calibration nozzle required for calibration of trolley on rear
side of the machine.
- Mount calibration nozzle.
- Remove trolleys from configuration.
3002 %1 :\tPre-calibration violation
For a correct calibration is a
certain hierarchy in calibration
steps needed. This hierarchy is
not followed. - Illegal calibration executed.
- Execute auto calibration.
- Execute correct exchange calibration.
3003 %1 :\tCamera tolerance problem
The measured characteristics of
the camera (pixel-size, etc.) differ
to much from the specified values. - Defect camera or badly connected camera. - Check connections.

3004
%1 :\tFA Front-right Rear-right
tolerance
The measured distance between
the FRONT-RIGHT and the REAR-
RIGHT head-marker is out of
tolerance.
- Not correctly mounted /calibrated marker reference plate.
- Not correctly mounted /calibrated FA camera. Check connection of modules and re-calibrate machine.
3005 %1 :\tCA H-mark tolerance
The measured distance between
markers on the component
alignment reference plate,
measured with the FA and CA
camera's is out of tolerance.
- Reference plate not correctly mounted.
- Camera's not correctly mounted.
- Check camera fixation.
- Check reference plate connection.
3006 %1 :\tCA/FA mark tolerance
The measured distance between
markers on the component
alignment reference plate,
measured with the FA and CA
camera's is out of tolerance.
- Reference plate not correctly mounted.
- Camera's not correctly mounted.
- Check camera fixation.
- Check reference plate connection.
3007 %1 :\tCA-Z tolerance
Z-level of CA camera is not
correct. - CA unit mechanically not adjusted. - Adjust CA camera.
3008 %1 :\tHead FA tolerance
The head marker characteristics
measured by the FA camera are
out of tolerance - Placement head incorrectly mounted. - Re-mount placement head and re-calibrate.
3009 %1 :\tZ-position tolerance Z calibration is out of tolerance. - The measured Z-level is not correct. - Check module Z-level
3010 %1 :\tXY-position tolerance
Requested XY-position is ou of
tolerance. - Internal software error; mismatch data-file! - Re-initialize machine. If not correct contact your service representative.
3011 %1 :\tFile-I/O error
The package type description has
not the correct syntax. - Not updated or illegal updated package description.
- Re-install package.
- Use Setup-Vision to update package.
3012 %1 :\tNo FA package found
The package definition needed to
calibrate is not available. - Package not installed. - Install package, copy from archieve
3013 %1 :\tNo CA package found
The package definition needed to
calibrate is not available. - Package not installed. - Install package, copy from archieve.
3014 %1 :\tNo nozzle
To execute this calibration, a
nozzle is needed. - No nozzle mounted on head used for (trolley) calibration.
- Execute toolbit (nozzle) exchange
- Remove not needed trolleys from configuration
3015 %1 :\tComp on nozzle
A component is picked by the
nozzle.
- Pick process is interrupted.
- Component not removed after vision setup functions. - Remove component
3016 %1 :\tCA: No component found
The expected component can not
be detected in the component
image.
- Calibration nozzle not mounted in head.
- Light level not calibrated.
- Z-level not calibrated.
- Check calibration nozzle.
- Check whether all pre-conditions are full-filled.
3017 %1 :\tCA: No calibration marker
No calibration marker detected on
CA reference plate. Distorted marker. Clean marker plate.
3018 %1 :\tNo marker found
The calibration marker is not
found.
- FA camera is not correctly positioned above marker.
- Dirt on the calibration marker.
- Fiducial file used by the vision system is not correct (light
level, threshold etc.)
- Check in Setup-Vision the maker detection.
- Check the calibration marker.
- Check the position of the camera.
3019 %1 :\tMarker search fail
The calibration marker searched
by the calibration function could
not be found.
- Module (e.g. transport calibration plate, feeder section ) not
available.
- Illegal/incorrect update of system files.
- Check availability of modules and markers.
- Re-install.

3020 %1 :\tXY-calibration table errors
During X-Y calibration errors are
detected. - Distorted markers on calibration plate. - Fix calibration table.
3021 %1 :\tTransport error
The transport module does not
respond correctly. - Incorrectly installed transport system. - Check transport module.
3022 %1 :\tToolbit present
A toolbit is attached in the head.
For this calibration no toolbit must
be attached. - Toolbit attached. - Detach toolbit.
3023 %1 :\tVacuum flow too high
The vacuum calibration, executed
on a head without a nozzle, gives
a value which is too high. - Filthiness of the measurement restriction. - Check vacuum system (especially the measurement restriction).
3024 %1 :\tNothing to repair
The X-Y calibration is correct, no
extra actions are needed. - Calibration is correct. - None.
3025
%1 :\tNo calibration nozzle at front
side
The calibration nozzle, needed at
front side head, is not mounted. - Not or incorrectly mounted nozzle. - Mount calibration nozzle at front size.
3026 %1 :\tNo rear nozzle
The calibration nozzle, needed at
rear side head, is not mounted. - No or incorrectly mounted nozzle. - Mount calibration nozzle at rear side
3027 %1 :\tCA Camera not configured
The camera needed for calibration
is not configured - Non-configured camera. - Configure camera in human interface (SETUP-CONFIGURATION).
3028
%1 :\tToolbit eccentricity is out of
tolerance - Change toolbit.
3029 %1 :\tZ-Level calibration failed Z-Level calibration failed.
- If head, then head not correctly mounted on the machine.
- If feeder section, then feederbank/trolley not correctly
mounted on the machine.
- Check height of the subframe.
- Re-adjust.
3030 %1 :\tForce table calibration failed Force table calibration failed. - Hardware error.
- Check hardware.
- Retry action. If not correct, contact your service representative.
3031
XY-Calibration plate reference
marker not found
The marker on the XY-Reference
plate could not be located. - Marker is damaged. - Check marker.
3032 %1 :\tPlacement action interrupted
The placement action is
interrupted due to a machine
failure. This may have led to a
wrong placement. - Machine error.
- Check if component was placed correctly. If so, select skip action, otherwise
select retry.
3033 %1 :\tVacuum flow too low
The vacuum calibration, executed
on a head without a nozzle, gives
a value which is too low.
- Obstruction in vacuum system.
- Obstruction in pipette.
- Jammed vacuum tube. - Check pipette and vacuum system.
3034
Calibration slide temp tolerance
error Temperature tolerance error. - Temperature under 0 Celcius or above 60 Celcius. - Report error to your service representative.
3100
%1 :\tModule configuration file
missing on aPC
The configuration data needed for
this module is not available.
- Incorrect installation.
- Files removed from the filesystem. - Re-install software.
3101
%1 :\tInvalid configuration file:
Invalid syntax version
The installed configuration file has
an illegal syntax number. - The installation is not executed properly. - Re-install software.
3102
%1 :\tInvalid module configuration
file: Section missing
The configuration file for this
module is not correct.
- Incorrect installation.
- Files removed from the filesystem. - Re-install software
3103
%1 :\tInvalid module configuration
file: Entry missing
The configuration file for this
module is not correct.
- Incorrect installation
- Files removed from the filesystem - Re-install software