3139 %1 :\tComponent size or angle out of limits Component size or angle does not comply with component description. - Wrong description. - Bad component. - Adapt component description : check body tolerance and reject l…

3123 %1 :\tToolbit not attached
The needed toolbit for production
is not attached to head or the
toolbit file is not correct.
- The correct toolbit is not attached
- Illegal updated toolbit file
- Not correct installed toolbit file
- Attach toolbit to head
- Re-install toolbit file
3124
%1 :\tUnexpected error occurred
in Module
The indicated module could not be
initialized. - Error on module. - Remove module from configuration and re-configure.
3125
%1 :\tController detected error
during action Internal software error. - Retry.
3126 %1 :\tController is in wrong state Internal software error. - Retry.
3127
%1 :\tIncorrect parameter sent to
controller
Control software sent incorrect
data to controller.
- Incorrect action spec (feeder 0 specified).
- Incorrect firmware.
- Check action spec.
- Check firmware version.
3128
%1 :\tThe firmware command is
not yet supported
A command is given to firmware
that is not implemented yet, or is
unknown. - Not documented commands are used. - Use correct commands.
3129 %1 :\tFirmware refused
The firmware specified in the
configuration is not correct. - Illegal update of firmware. - Re-install software.
3130
%1 :\tUnsupported command is
given to the controller
An unsupported command is given
to the controller. - Internal software error. - Report error to your service representative.
3131
%1 :\tController timed out during
action
The controller response is not
within a certain time window.
- Incorrect movement class.
- Incorrect speed mode.
- Check action spec.
- Check package type database.
3132 %1 :\tIncorrect toolbit type in head Unknown toolbit inserted in head. - Unsupported toolbit type inserted in head. - Replace toolbit with correct one.
3133 %1 :\tbitbus node not found The bitbus node is not found. - Module not connected to bitbus. - Check bitbus connection cable.
3134
%1 :\tNot able to disconnect
controllers Not able to disconnect controllers.
- Bitbus error.
- Software error.
- Shutdown system.
- Restart the system.
3135
%1 :\tPosition of servo system
outside limits
One or more servo systems were
attempted to move outside it
physical range or the tolerance on
the nominal position is too large.
- An error in the action spec.
- Calibration error.
- Mechanical adjustment incorrect.
- Check the action spec.
- Calibrate the specific module.
- Re-adjust and calibrate module.
3136 General servo power failure
All conditions for having servo
power are met but there's no servo
power present
( covers are closed,
feedersections are present, no
mains phase failure, no
emergency buttons pressed )
- Servo power not activated ( yet )
- Defective CAN card, defective LIMMS controller or missing
CAN terminator
- Power failure, defective power supply
- Press 'Servo power On' button
- Check aPC errors, see error descriptions in the Service Manual ( contact your
service representative in case of doubts )
- Check leds on LIMMS Power Supply, see Service Manual
- Check fuses, power supply and safety rel
3137
Invalid or inconsistent SBIP entry
parameters
SBIP encountered invalid
parameter values.
- Component id not known by SBIP.
- Component / fiducial file to download not found on APC.
- Illegal component type specified in component description.
- Check component / fiducial file descriptions.
- Report error to your service representative.
3138 Spurious SBIP error encountered
An unidentified error occurred on
the SBIP.
- Retry action.
- Check vision file.
- Shutdown and restart the system.
- Report error to your service representative.

3139
%1 :\tComponent size or angle out
of limits
Component size or angle does not
comply with component
description.
- Wrong description.
- Bad component.
- Adapt component description : check body tolerance and reject level phi
settings.
- Inspect component.
3140
%1 :\tNot enough free space
around fiducial
The interpolation (or 'Synthetic
Edge') algorithm requires a
minimum free space of 40 pixels
around the fiducial
- Board is dirty near the fiducials.
- Bad light conditions.
- Clean fiducial.
- Adapt light setting in fiducial description file.
3141
File access error for verification
log file
In accessing the verification log file
an error has occurred.
- The verification directory on the APC does not exist.
- Disk full.
- An error occurred in the file system.
- Check whether the verification directory on the aPC exist.
- Check the disk space.
- Repeat the verification measurement.
3142
Calibration at rear side cannot be
performed - switch calibration
nozzles
- The requested calibration is only
partly completed.
- Nozzles need to switched to the other machine side.
- This calibration actually requires 4 calibration nozzles for a
fully equipped machine.
- Remove calibration nozzles and mount them on the other machine side.
- Continue with rest of calibration by performing an automatic calibration.
3143 %1 :\tComponent on nozzle
If this message occurs, the
machine tries to calibrate the
vacuum of the nozzle. A
component is on the nozzle so the
nozzle can not be calibrated. - Unexpected component on the nozzle.
- Take component of the nozzle.
- Retry the action.
3144 %1 :\tExternal position error
External
position error
The Y axis detected that the
external encoder input signal from
the X axis was not correct.
- Bad connection of the X encoder signal to the Y axis.
- Defective external encoder input circuit on the Y axis.
- Select retry.
- If the problem keeps re-occurring, see Service Manual.
3145 %1 :\tComponent not measured Error in system call sequence - Bad processing sequence
- Retry action
- Report error to your service representative.
3146 %1 :\tFlux applicator not stopped
Flux applicator did not respond on
STOP/CLAIM command.
- Stop command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry the operation.
3147
%1 :\tFirst component lead not
found
The first lead, used as reference,
can not be detected.
- Wrong component attached.
- Wrong component description used.
- Wrong index feeder for tape components.
- Wrong pitch tray for tray components.
- Orientation of the component in feeder not correct.
- Bad contrast
- Verify component and component description in the setup vision menu using
the show definition function, check reject level !
- Check index of the feeder.
- Check the pitch of the tray with the one specified in the action spec.
- Check the orientation
3148 %1 :\tFlux applicator is not rotating
The flux applicator did not start
rotating.
- Start command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry operation.
3149
%1 :\tComponent mismatch
(second lead)
Mismatch between the component
description and the measured
component characteristics.
(Second lead).
- Wrong component attached.
- Wrong component description used.
- Wrong pick-up position.
- Verify component and component description by SHOW function.
- Check the pick-up position.

3150
%1 :\tDust cover not on flux
applicator
The dust cover has not been
attached properly to the flux
applicator.
- Flux applicator switched off.
- Cover not on flux applicator.
- Defective EPD.
- Defective EPD-wiring.
- Switch on flux applicator.
- Check if the dust cover is in the correct position.
- Check EPD.
- Check wiring.
- Retry operation.
3151
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component characteristics.
Number of leads.
- Wrong component attached.
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
3152 %1 :\tUnexpected stopped disk
The flux applicator disks are
stopped while not expected
- Flux applicator disks jammed.
- Connection failure.
- Clean flux applicator disks.
- Check wiring.
3153
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component characteristics.
Number of leads
- Wrong component attached
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
3154 %1 :\tUnexpected started disk
Flux applicator disks started while
not expected. - Wiring not correct. - Check wiring.
3155 %1 :\tLead end not found.
The component lead end can not
be found.
- Wrong component attached.
- Wrong component description used, modify lead end
parameter. - Verify component and component description by SHOW function.
3157 %1 :\tLead spacing not correct.
Mismatch between the defined
lead spacing and the measured
lead spacing.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
3158
%1 :\tNo free location found in
Toolbit exchange unit to put
current toolbit in
No free location in toolbit
exchange unit. - All positions in toolbit exchange unit in use. - Free one position.
3159 %1 :\tLead width not correct
Mismatch between the defined
lead width and the measured lead
width.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
3161 %1 :\tComponent leads skewed.
The lead skewing is out of
tolerance. - Component leads are skewed. - Verify component and component description by SHOW function.
3163
%1 :\tComponent size or angle out
of limits
Component size or angle does not
comply with component
description.
- Wrong description.
- Bad component.
- Adapt component description : check body tolerance and reject level phi
settings.
- Inspect component.
3165
%1 :\tComponent can not be
recognized Component can not be found
- Wrong component attached
- Wrong component description used.
- Bad contrast, image too dark
- Verify component and component description by SHOW function.
- Change illumination level or type
3166
%1 :\tSpecified toolbit location in
toolbit exchange unit is empty
No toolbit is found in the desired
toolbit exchange location. - The specified toolbit exchange location is empty.
- Put the desired toolbit in the toolbit exchange location, use SETUP - TOOLBIT
functions.