3150 %1 :\tDust cover not on flux applicator The dust cover has not been attached properly to the flux applicator. - Flux applicator switched off. - Cover not on flux applicator. - Defective EPD. - Defective EPD-wiring. …

3139
%1 :\tComponent size or angle out
of limits
Component size or angle does not
comply with component
description.
- Wrong description.
- Bad component.
- Adapt component description : check body tolerance and reject level phi
settings.
- Inspect component.
3140
%1 :\tNot enough free space
around fiducial
The interpolation (or 'Synthetic
Edge') algorithm requires a
minimum free space of 40 pixels
around the fiducial
- Board is dirty near the fiducials.
- Bad light conditions.
- Clean fiducial.
- Adapt light setting in fiducial description file.
3141
File access error for verification
log file
In accessing the verification log file
an error has occurred.
- The verification directory on the APC does not exist.
- Disk full.
- An error occurred in the file system.
- Check whether the verification directory on the aPC exist.
- Check the disk space.
- Repeat the verification measurement.
3142
Calibration at rear side cannot be
performed - switch calibration
nozzles
- The requested calibration is only
partly completed.
- Nozzles need to switched to the other machine side.
- This calibration actually requires 4 calibration nozzles for a
fully equipped machine.
- Remove calibration nozzles and mount them on the other machine side.
- Continue with rest of calibration by performing an automatic calibration.
3143 %1 :\tComponent on nozzle
If this message occurs, the
machine tries to calibrate the
vacuum of the nozzle. A
component is on the nozzle so the
nozzle can not be calibrated. - Unexpected component on the nozzle.
- Take component of the nozzle.
- Retry the action.
3144 %1 :\tExternal position error
External
position error
The Y axis detected that the
external encoder input signal from
the X axis was not correct.
- Bad connection of the X encoder signal to the Y axis.
- Defective external encoder input circuit on the Y axis.
- Select retry.
- If the problem keeps re-occurring, see Service Manual.
3145 %1 :\tComponent not measured Error in system call sequence - Bad processing sequence
- Retry action
- Report error to your service representative.
3146 %1 :\tFlux applicator not stopped
Flux applicator did not respond on
STOP/CLAIM command.
- Stop command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry the operation.
3147
%1 :\tFirst component lead not
found
The first lead, used as reference,
can not be detected.
- Wrong component attached.
- Wrong component description used.
- Wrong index feeder for tape components.
- Wrong pitch tray for tray components.
- Orientation of the component in feeder not correct.
- Bad contrast
- Verify component and component description in the setup vision menu using
the show definition function, check reject level !
- Check index of the feeder.
- Check the pitch of the tray with the one specified in the action spec.
- Check the orientation
3148 %1 :\tFlux applicator is not rotating
The flux applicator did not start
rotating.
- Start command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry operation.
3149
%1 :\tComponent mismatch
(second lead)
Mismatch between the component
description and the measured
component characteristics.
(Second lead).
- Wrong component attached.
- Wrong component description used.
- Wrong pick-up position.
- Verify component and component description by SHOW function.
- Check the pick-up position.

3150
%1 :\tDust cover not on flux
applicator
The dust cover has not been
attached properly to the flux
applicator.
- Flux applicator switched off.
- Cover not on flux applicator.
- Defective EPD.
- Defective EPD-wiring.
- Switch on flux applicator.
- Check if the dust cover is in the correct position.
- Check EPD.
- Check wiring.
- Retry operation.
3151
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component characteristics.
Number of leads.
- Wrong component attached.
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
3152 %1 :\tUnexpected stopped disk
The flux applicator disks are
stopped while not expected
- Flux applicator disks jammed.
- Connection failure.
- Clean flux applicator disks.
- Check wiring.
3153
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component characteristics.
Number of leads
- Wrong component attached
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
3154 %1 :\tUnexpected started disk
Flux applicator disks started while
not expected. - Wiring not correct. - Check wiring.
3155 %1 :\tLead end not found.
The component lead end can not
be found.
- Wrong component attached.
- Wrong component description used, modify lead end
parameter. - Verify component and component description by SHOW function.
3157 %1 :\tLead spacing not correct.
Mismatch between the defined
lead spacing and the measured
lead spacing.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
3158
%1 :\tNo free location found in
Toolbit exchange unit to put
current toolbit in
No free location in toolbit
exchange unit. - All positions in toolbit exchange unit in use. - Free one position.
3159 %1 :\tLead width not correct
Mismatch between the defined
lead width and the measured lead
width.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
3161 %1 :\tComponent leads skewed.
The lead skewing is out of
tolerance. - Component leads are skewed. - Verify component and component description by SHOW function.
3163
%1 :\tComponent size or angle out
of limits
Component size or angle does not
comply with component
description.
- Wrong description.
- Bad component.
- Adapt component description : check body tolerance and reject level phi
settings.
- Inspect component.
3165
%1 :\tComponent can not be
recognized Component can not be found
- Wrong component attached
- Wrong component description used.
- Bad contrast, image too dark
- Verify component and component description by SHOW function.
- Change illumination level or type
3166
%1 :\tSpecified toolbit location in
toolbit exchange unit is empty
No toolbit is found in the desired
toolbit exchange location. - The specified toolbit exchange location is empty.
- Put the desired toolbit in the toolbit exchange location, use SETUP - TOOLBIT
functions.

3167
%1 :\tComponent Mismatch
(sides)
Mismatch between the component
description and the measured
component characteristics.
Distance between the sides - Wrong component description used. - Verify component and component description by SHOW function.
3168
%1 :\tOne or more component
side(s) not found
One or more component side(s)
could not be recognized
- Wrong component attached
- Wrong component description used
- Search window too small (reject level)
- Bad lighting conditions
- Verify component and component description by SHOW function
- Adjust reject level
- Adjust light levels
3169 %1 :\twrong shape
- No correct shape can be
deducted from sides. - Recognized sides do no intersect. - Check component description.
3170
%1 :\tLine fit error on component
side Cannot fit line on recognized side
- Wrong component attached
- Wrong component description used
- Bad light settings
- Ruler intersection not on one line
- Verify component and component description by SHOW function
- Change illumination level or type
- Change threshold
- Change ruler offset
3171 %1 :\tComponent lost before flux
Component is lost before the flux
is applied.
- Wrong toolbit is used.
- Vacuum leakage in the toolbit.
- Look where the component is. When on head, leave it there, it will be
dumped automatically on the re-use pallet.
- Check used toolbit for vacuum leakage.
- Retry.
3172 %1 :\tComponent lost after flux
Component is lost after applying
flux to it.
- Wrong toolbit is used.
- Vacuum leakage in the toolbit.
- Too much flux on drum.
- Look where the component is. When on head, leave it there, it will be
dumped automatically on the reuse pallet.
- Check used toolbit for vacuum leakage.
- Retry.
3173
%1 :\tToolbit too big to fit in toolbit
exchange unit
Toolbit does not fit in toolbit
exchange unit.
Putting this toolbit in the toolbit
exchange unit may cause serious
damage to the toolbit, head or
toolbit exchange unit. - Not supported toolbit size. - Exchange the toolbit manually.
3174 %1 :\tFiducial not measured
The fiducial could not be
measured by the vision system.
- No fiducial has been found.
- Bad colour (polarity) of fiducial (Black or White).
- Wrong light level.
- Check the fiducial by using the setup vision menu, to see if the light level and
the polarity are correctly specified in the fiducial file.
- Check if the board is stopped on the correct position in the transport system.
- Re-position FA camera (by ad
3175
%1 :\tRequested toolbit not found
in Toolbit exchange unit
The needed toolbit is not available
in Toolbit exchange unit. _The needed toolbit is not available. - Put toolbit in unit, use SETUP - TOOLBIT functions.
3176 %1 :\tFiducial size not correct
Mismatch between measured
fiducial size and measured size.
- Wrong fiducial.
- Wrong description. - Modify description.