ERR-LIST-ACM - 第47页

3190 %1 :\tno bump match - Number of bumps is too large for bump checking algorithm. - No bump present or too many bumps (objects) found at expected position. - Bad component quality. - Adjust matrix definition. - Check …

100%1 / 52
3177 %1 :\tUnexpected toolbit attached
Toolbit attached to the head, while
trying to get a new toolbit from the
toolbit exchange unit.
- Toolbit not removed from the head during toolbit exchange
action.
- Remove toolbit manually, or
- Retry toolbit exchange action.
3178
%1 :\tNot enough free space
around fiducial
The interpolation (or 'Synthetic
Edge') algorithm requires a
minimum free space of 40 pixels
around the fiducial.
- Board is dirty near the fiducials.
- Bad light conditions.
- Clean fiducial.
- Adapt light setting in fiducial description file.
3179
%1 :\tImage quality not good
enough for feature recognition
Too many black/white crossovers
in image, or contrast too low to
recognize bumps.
- Lighting (level and type of illumination) or threshold settings
are wrong.
- Component features out of spec.
- Change bump threshold settings : higher for too bright images / lower for too
dark images.
- Change illumination level and/or type.
3180
%1 :\tImage quality not good
enough for feature recognition
Too many black/white crossovers
in image, or contrast too low to
recognize bumps.
- Lighting (level and type of illumination) or threshold settings
are wrong.
- Component features out of spec.
- Change bump threshold settings : higher for too bright images / lower for too
dark images.
- Change illumination level and/or type.
3181
%1 :\tComponent outline detection
failed
The initial estimation of the
component contour (based on
outer bumps) failed.
- Bump area limits not correctly specified.
- Too many disturbing (bright) objects at border of component.
- Check specified bump areas.
- Change illumination type or intensity.
3182
%1 :\tComponent outline detection
failed
The initial estimation of the
component contour (based on
outer bumps) failed.
- Bump area limits not correctly specified.
- Too many disturbing (bright) objects at border of component.
- Check specified bump areas.
- Change illumination type or intensity.
3183 %1 :\tbump line fitting failed
- The bumps used for alignment
cannot be fitted on one line.
- Bumps are not located on one line.
- There are less than 2 bumps for a particular component side.
- Change bump alignment parameters in component description (threshold,
light intensity, border range).
3184 %1 :\tbump line fitting failed
- The bumps used for alignment
cannot be fitted on one line.
- Bumps are not located on one line.
- There are less than 2 bumps for a particular component side.
- Change bump alignment parameters in component description (threshold,
light intensity, border range).
3185
%1 :\tNot enough bumps for
alignment
- The initial number of detected
bumps in the border range is not
enough to start alignment on.
- The initial number of detected bumps on one side is less than
the defined minimum number of alignment bumps
for that side.
- Define lower number of required alignment bumps.
- Improve light settings and/or threshold or bump area definitions.
3186
%1 :\tNot enough bumps for
alignment
- The initial number of detected
bumps in the border range is not
enough to start alignment on.
- The initial number of detected bumps on one side is less than
the defined minimum number of alignment bumps for that side.
- Define lower number of required alignment bumps.
- Improve light settings and/or threshold or bump area definitions.
3187 %1 :\tbump pattern too large
- Number of bumps is too large for
bump checking algorithm. - Too many or too large bump matrices specified. - Define less matrices or bumps.
3188 %1 :\tbump pattern too large
- Number of bumps is too large for
bump checking algorithm. - Too many or too large bump matrices specified. - Define less matrices or bumps.
3189 %1 :\tno bump match
- One or more bumps cannot be
matched with expected bump
during bump checking.
- No bump present or too many bumps (objects) found at
expected position.
- Bad component quality.
- Adjust matrix definition.
- Check component quality.
3190 %1 :\tno bump match
- Number of bumps is too large for
bump checking algorithm.
- No bump present or too many bumps (objects) found at
expected position.
- Bad component quality.
- Adjust matrix definition.
- Check component quality.
3191
%1 :\tToolbit too big for coplanarity
actions
Toolbit does not fit in the
coplanarity unit. Using this toolbit
for coplanarity actions may cause
serious damage to the toolbit,
head or coplanarity unit. - Not supported toolbit size Update action spec
3192
%1 detected an unexpected
collision
During Toolbit exchange, the head
detected an impact with an object
while lowering the head. - A toolbit is in a toolbit exchange location that should be empty.
- Update the toolbit exchange data, or
- Remove / replace the unexpected toolbit from the toolbit exchange unit.
3193 %1 did not detect a touchdown
The head did not detect an impact
within the specified search area.
- The impact surface is not present.
e.g. during picking from tray, no component is present in tray
pocket.
during fetching a toolbit while executing a toolbit
exchange, no toolbit is present in the toolbit pocket - Check if the requested part is present on the machine.
3195 Invalid feeder file
The system encountered invalid
data in a feeder control file of a
feeder that is used in the action
spec.
- Syntax error in feeder control file.
- Value out of range. - Check the feeder file.
3197 %1 :\tFeeder in error
One of feeders in the feeder
section reported an error. - Problem on feeder. - Solve the error cause.
3199
Restoring XY calibration data
failed
The data to restore has arrived on
the aPC, but the processing of this
data has failed.
- Original data could not be backed up.
- Current calibration values could not be invalidated.
- New calibration data could not be used.
- If the original data files were all backed up, restore these files manually and
restart the machine.
- Otherwise, the machine still has valid calibration data. Try to restore again
when the problem that caused the backup to fail is solved.
3200 MIS data collection failed
The MIS data collection failed, no
MIS data is retrieved from the
system. The MIS data for this
order period is not reliable.
- Disk full.
- Illegal file modifications by user.
- System communication error.
- No current order available on the system, or no previous order
selected.
- Check disk capacity.
- Check if there is a current order on the system, or if one is selected.
3201
RETRY INFORMATION\x0ANo
extra information available
3202
RETRY INFORMATION\x0AHead
: %1\x0ASection : %2\x0AFeeder :
%3\x0AChannel :
%4\x0AComponent : %5\x0A
3203
RETRY
INFORMATION\x0ASection :
%1\x0AFeeder : %2\x0AChannel :
%3\x0AToolbit : %4\x0ANozzle :
%5\x0AVacuum specified :
%6\x0AVacuum measured :
%7\x0AComponent : %8\x0A
3204 The recovery action failed
One or more errors (possible the
same as the original one(s))
occurred during the error recovery
action.
3205
Head: %1\x0ASection:
%2\x0AFeeder: %3\x0AChannel:
%4\x0AComponent:
%5\x0APackage: %6\x0A
3206
RETRY INFORMATION\x0AHead:
%1\x0ASection: %2\x0AFeeder:
%3\x0AChannel:
%4\x0AComponent:
%5\x0APackage: %6\x0A
3207 No active MIS period available
There is no active MIS period, so
the operation cannot be executed.
- The current MIS period is not started yet.
- Inconsistency in internal administration.
- Start production and enter a board.
- Delete current order, start new order and resume production.
3208
Measured: %1 mm.\x0ALower
limit: %2 mm.\x0AUpper limit: %3
mm.\x0A
3209
RETRY
INFORMATION\x0AMeasured:
%1 mm.\x0ALower limit: %2
mm.\x0AUpper limit: %3 mm.\x0A
3210
RVS :\tthis function (%d) has not
been implemented (yet).
A function was activated that has
not been implemented in the
current software version.
- Functions that are not complete yet should not be accessible
for the user.
- By mistake, this function is accessible for the user.
- Clear the error and do not use the functions again.
- Report the error to your service representative.
3211
RVS :\t system communication
error on: %d. A system error occurred. Unknown.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
3212
Component description
incompatible with CA-camera type
The component description is
incompatible with the CA-camera
used.
- The component type is specified for use on only one of the
camera types (LFOV-SFOV) and an attempts is made to use
the component with the other camera type.
- Use the appropriate camera type, or
- Modify the component description.
3213
Error in merging vision data with
action spec data.
Unable to update action spec with
modified vision data. - Not consistent system data.
- Remove order from system.
- If this problem occurs frequently, contact service representative.