6.2.13. Inspect Stencil Stager Clamp PlatesMonthly
Figure 147. Inspect Stencil Stager Clamp Plates.
Introduction
Inspect the condition of the stencil stager clamp plates
Estimated Completion Time
Less than 5 minutes
Procedure
Inspect and clean the two horizontally-mounted stencil stage clamp plates (Figure 147).
o Clean the plate surfaces using isopropyl alcohol and a brush.
Normal plate wear indications:
o Round circles, slightly black in color.
o Circles about 30 mm size.
Streaking indicates required clamp maintenance. If plates are streaked:
o Maintain the clamp assembly on the side showing streaking.
o Contact the Technical Support Center (see Section 1.2) for the proper clamp assembly
maintenance procedure.
Normal plate wear indicators: Black circles, roughly 30mm diameter.
Edison Printer User Manual (Part Number 1023838) MAINTENANCE
Rev. A 149
Copyright © 2017 ITW EAE
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of ITW EAE, unless for purchaser's personal use.
MAINTENANCE Edison Printer User Manual (Part Number 1023838)
150 Rev. A
Copyright © 2017 ITW EAE
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of ITW EAE, unless for purchaser's personal use.
6.2.14. Inspect Stencil Alignment Clamp PlatesMonthly
Figure 148. Inspect stencil alignment clamp plates.
Introduction
Inspect the condition of the stencil alignment clamp plates.
Estimated Completion Time
Less than 5 minutes
Procedure
Inspect and clean the two vertically-mounted stencil stage clamp plates.
o Clean the plate surfaces using isopropyl alcohol and a brush.
Normal plate wear indications:
o Round circles, slightly black in color.
o Circles about 30 mm size.
Streaking indicates required clamp maintenance. If plates are streaked:
o Contact the Technical Support Center (see Section 1.2) for the proper clamp assembly
maintenance procedure.