retrieval systems without the written permission of ITW EAE, unless for purchaser's personal use.
6.2.24. Inspect EdgeLoc+ System SpringsMonthly
Figure 158. Inspect EdgeLoc+ System Springs.
Introduction
Verify the condition of the springs used in the EdgeLoc + system for compliance monthly.
Estimated Completion Time
Less than 5 minutes.
Procedure
Each of the four springs (one at each corner) of the EdgeLoc+ assemblies are assist springs to pull
down the assembly when released (Figure 158).
Inspect and verify:
The springs are in place.
The springs do not appear stretched out.
Edison Printer User Manual (Part Number 1023838) MAINTENANCE
Rev. A 161
Copyright © 2017 ITW EAE
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of ITW EAE, unless for purchaser's personal use.
6.2.25. Inspect Solvent Return TroughMonthly
Figure 159. Inspect Solvent Return Trough.
Introduction
Inspect solvent return trough for debris and clean for proper drainage (Figure 159).
Estimated Completion Time
Less than 5 minutes.
Procedure
Inspect the drainage return port in the center of the return trough for contamination by paste
or wiper paper debris.
o If the drainage return port is blocked, solvent can overflow into the catch tray.
Clean the port.
Cycle the solvent system by the I O pull-down maintenance feature.
o Solvent should pump into the return trough and then be drawn down through the port
then to the solvent tank.
o Run this for two minutes while observing the return.
MAINTENANCE Edison Printer User Manual (Part Number 1023838)
162 Rev. A
Copyright © 2017 ITW EAE
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of ITW EAE, unless for purchaser's personal use.
6.2.26. Inspect Vacuum Plenum and ChamberMonthly
Figure 160. Inspect vacuum plenum and chamber.
Introduction
Inspect and clean vacuum plenum and chamber (Figure 160).
Estimated Completion Time
Less than 5 minutes.
Procedure
Examine and clean the Wipe plenum:
Remove plenum and inspect for excessive debris and clean.
Check O-ring integrity
o Re-apply vacuum grease.
Inspect vacuum chamber for excessive debris and clean.
Ensure plenum is re-installed in the correct direction:
o Flat edge toward front of machine.