1 WF 4 TX-Series V2 Maintenance Test the tape cutter 2 min 1 / 3 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine S…

www.asm-smt.com

1 WF 4 TX-Series V2 Maintenance Test the tape cutter 2 min 1 / 3
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C1
www.asm-smt.com
1 Stop the production and click on "Block
conveyor".
2 Block both lanes and click on "OK". 3 Click on "Maintenance".
4 Click on "Check tape cutters". 5 Press the stop button. 6 Open the covers.

1 WF 4 TX-Series V2 Maintenance Test the tape cutter 2 min 2 / 3
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C1
www.asm-smt.com
7 Insert a paper (A3) in both tape cutters. 8 Close the covers. 9 Select both tape cutters and click on
"Start".