Guidelines for using PPS-Pro
3.2.10 Miscellaneous
3.2.10.1 C:\temp directory does not exist
Description: If the ‘C:\temp’ directory doesn’t exist, the following error
occurs: ‘Optimizer Error: 1001: Error created directory C:\TEMP\emt_temp,
status -1’.
Advice: Create the ‘C:\temp’ directory.
3.2.10.2 BVM1Index - Set Attributes
When the ‘BVM1Index’ is set to ‘Yes’ in the ALE attributes then it indicates
that all fiducial actions which belong together (for a circuit or group) must be
done in the same index step. Because the transport system performs no inter
-
mediate steps between the BVM measurements, the correction for the
particular fiducial arrangement is more accurate, and therefore leads to a
better placement accuracy. This does not mean that the BVM actions must be
done in the first index.
3.2.11 How to use transport settings for FCM
The transport of a pcb through an FCM is carried out by the transport beam
with a carrier set on it. In normal circumstances the default index schemes
(see 3.2.11.1 on page 100) are used. However if a special index scheme is
required it can be specified in the PPS Machine Specific settings.
Every step of the scheme represents a step (move in x-direction) of the beam
in an FCM.
3.2.11.1 Default FCM index schemes
These values are tuned for ‘DFA/BMS’ usage on the FCM (see TABLE 6 on page
101).
Pitch Max X PCB
Stopper in X
position
Boards
index step size (mm)
x01 x02xx03xx04xx05xx06xx07xx08
120 114 -341 20 60 60
130 124 -301 18 60 70
140 134 -201 16 70 70
150 144 -311 16 70 80
160 154 -301 15 80 80
170 164 -271 14 50 60 60
180 174 -261 13 60 60 60
190 184 -191 12 60 60 70
200 194 -281 12 60 70 70
210 204 -201 11 70 70 70
220 214 -261 11 70 70 80
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 101
Guidelines for using PPS-Pro
TABLE 6 Default FCM index schemes
SCREEN 60 PCB Pitch
NOTE: Use alternative if these constraints can not be obeyed.
1) The second fiducial (left) can be reached in index 1 if the distance between
second fiducial (left) and the SE point is less than 380 mm.
2) The second fiducial (left) can be reached in index 1 if the distance between
second fiducial (left) and the SE point is less than 400 mm.
230 224 -171 10 70 80 80
240 234 -221 10 80 80 80
250 244 -101 9 60 60 60 70
260 254 -181 9 60 60 60 80
270 264 -221 9 60 60 70 80
280 274 -101 8 60 60 80 80
290 284 -161 8 70 70 70 80
300 294 -161 8 70 70 80 80
310 304 -171 8 70 80 80 80
320 314 -101 7 60 60 60 60 80
330 324 -101 7 60 60 70 70 70
340 334 -121 7 60 80 80 60 60
350 344 -161 7 80 80 70 60 60
360 354 -161 7 80 80 80 60 60
380 374 -41 6 0 60 80 80 80 80
400
1
394 -121 6 60 60 60 60 80 80
Alternative 60 60 20 60 60 70 70
420
2
414 -101 6 60 60 80 80 70 70
Alternative 60 30 30 80 80 70 70
460
3
454 -41 5 0 60 80 80 80 80 80
Alternative (Not for FCM MF/ME) 0 60 0 80 80 80 80 80
480
4
474 -41 5 0 80 80 80 80 80 80
Pitch Max X PCB
Stopper in X
position
Boards
index step size (mm)
x01 x02xx03xx04xx05xx06xx07xx08
User Manual 4022 591 98247
102 PPS-Pro v8.2 05.07
Guidelines for using PPS-Pro
3) The second fiducial (left) can be reached in index 1 if the distance between
second fiducial (left) and the SE point is less than 400 mm. (Not for FCM MF/
ME)
4) The second fiducial (left) MUST be reached in index 1 if the distance
between the second fiducial (left) and the SE point is less than 400 mm. If not
DFA is not possible.
NOTE: Transport lift-up position equals –440 mm for all schemes. In these cases
stopper out must be used, so in the Machine or MachineClass attributes
section write: ‘TransportStopperOutUsed’ ‘YES’
3.2.11.2 Specify custom index scheme
If a special index scheme is required it can be specified in the PPS Machine
Specific settings
(see 3.2.11.3 on page 102).
Important parameters which must be defined are described below.
TransportStopperInX: An integer that specifies the X location of the
transport run-in stopper, relative to the machine origin.
TransportStopperOutUsed: Specifies whether the run-out stopper
should be used. Possible values are ‘Yes’ and ‘No’.
TransportBeamLiftupX: An integer that specifies the X location of the
beam liftup, relative to the machine origin.
TransportNrOfBoards: An integer that indicates the number of boards
on the beam.
TransportIndexStep: Specifies an array of integer values representing
the index steps (maximum 10 values). The sum of these steps
determine the board pitch.
There is a special order of importance of the specified index schemes, 1
overrules 2:
1. User defined project related transport settings (see 3.2.11.3 on page 102).
2. PPS defines default index schemes.
3.2.11.3 Specify project related transport settings
To specify the transport settings via the GUI of PPS-Pro the following things
must be done. Refer to Specify Project related optimizer settings
(see 2.25.1
on page 61).
To specify a new index scheme press the Add... button and the Add FCM
Transport Setting dialog appears
(see SCREEN 61 on page 103). Just fill in
every field in this dialog. After everything is specified, the name of the index