User Manual 4022 591 98247 152 PPS-Pro v8.2 05.07 Guidelines for using PPS-Pro A.3.4 AX machine Nozzles This table describes which Nozzles can be configur ed for an AX. F or Component Vision an a ddition Laser Align Nozz…

100%1 / 194
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 151
Guidelines for using PPS-Pro
TABLE 17 Nozzle for ACM, AQ and D-9
A.3.3.1 ACM, AQ and D9 TEU
On these 3 machine types a TEU (Toolbit Exchange Unit) CAN be defined. The
names of the TEU are not fixed (can be any name), but a good example would
be just TEU. These TEU contain 10 nozzle positions. On each position can be
any of the above-mentioned nozzles, depending on the size of the nozzle,
defined. The nozzles must be within a certain size (and shape!), otherwise
they don’t fit in the TEU.
TABLE 18 ACM, AQ-1,D-9 TUE / Nozzle relation
GS6 Special Gripper 6
GS7 Special Gripper 7
GS8 Special Gripper 8
GS9 Special Gripper 9
GS10 Special Gripper 10
GS11 Special Gripper 11
GS12 Special Gripper 12
GS13 Special Gripper 13
GS14 Special Gripper 14
GS15 Special Gripper 15
GS16 Special Gripper 16
GS17 Special Gripper 17
GS18 Special Gripper 18
GS19 Special Gripper 19
GS20 Special Gripper 20
<TEU> Nozzle
Position 1 Any Nozzle
Position 2 Any Nozzle
Position 3 Any Nozzle
Position 4 Any Nozzle
Position 5 Any Nozzle
Position 6 Any Nozzle
Position 7 Any Nozzle
Position 8 Any Nozzle
Position 9 Any Nozzle
Position 10 Any Nozzle
User Manual 4022 591 98247
152 PPS-Pro v8.2 05.07
Guidelines for using PPS-Pro
A.3.4 AX machine Nozzles
This table describes which Nozzles can be configured for an AX.
For Component Vision an addition Laser Align Nozzle must be available in the
toolbit exchange unit. This nozzle is used for Vacuum and Z Calibration. This
can be nozzle L2, l3, L4 or L5. Refer to
Table 19, “AX machine Placement
Robot / Nozzle relation,”
TABLE 19 AX machine Placement Robot / Nozzle relation
A.3.4.1 AX machine TEU
For each head/PM Type on the AX machine a TEU (Toolbit Exchange Unit)
MUST be defined. These TEU are named as follows: TEU<head number: 2
digits>. Examples: TEU01, TEU02 …. TEU11, TEU12 etc. These TEU contain 8
nozzle positions. Currently, the layout is fixed and looks as follows:
Regular
Nozzle
Name
Laser
Align
Component
Vision
Usable for
Vacuum and
Z Calibration
L1 X
L2 X X
L3 X X
L4 X X
L5 X X
L6 X
L7 X
L8 X
V3 X
V4 X
V5 X
V6 X
V7 X
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 153
Guidelines for using PPS-Pro
TABLE 20 AX machine Toolbit Exchange Unit / Nozzle relation
A.4 Feederbank Configurations
This chapter describes the possible feeder bank configurations for the various
machine types.
A.4.1 Feederbar Types
TABLE 21 Feederbar Name / Machine relation
TEU<xx> Nozzle
Position 1 Any Nozzle
Position 2 Any Nozzle
Position 3 Any Nozzle
Position 4 Any Nozzle
Position 5 Any Nozzle
Position 6 Any Nozzle
Position 7 Any Nozzle
Position 8 Any Nozzle
Feederbank Name FCM-II FCM-IIM FCMI-
IXM
ACM D9 AQ AX
FeederTrolley1 - - - X X - -
FeederBank1 - - - X X - -
TrayTrolley1 - - - X X - -
TrayPallet1 - - - X X - -
FeederBar_ITF X X X - - - -
ACM_Feeder_Bank - - - - X X -
ACM_Feeder_Trolley - - - - X X -
ACM_Tray_Pallet - - - - X X -
ACM_Tray_Trolley - - - - X X -
FCMII_upgrade - - - - - - X
A_Series_Feeder_Trolley X X