PPS Pro version 8.2 - 第168页

User Manual 4022 591 98247 164 PPS-Pro v8.2 05.07 Guidelines for using PPS-Pro A.6.3.2 AX Index Schemes F or the AX type machin es, th e optimizer will calculate the r equired inde x schem e (tran sport ind ex setting s)…

100%1 / 194
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 163
Guidelines for using PPS-Pro
A.6.2 Software Versions
Following is an overview of supported Program Formats by the optimizer:
TABLE 27 Program format for each machine type
A.6.3 Machine Specific Parameters
Per machine type, the following parameters can/have to be specified.
A.6.3.1 FCM Index Schemes
For the FCM type machines, the optimizer will calculate the required index
scheme (transport index settings). However, a user should be able to override
this by defining his own required index schema.
For FCM-II, FCM-IIM and FCM-IIXM machines, following parameters should be
user definable:
TABLE 28 ALE Settings Attributes for FCM-II, FCM-IIM and FCM-IIXM
Machine Type ProgramFormat
FCM-II 3 or 4
FCM-IIM 3 or 4
FCM-IIXM 3 or 4
ACM 3 or 4
D9 4
AQ-1 4
AX 1.11A, 1.10
Index Scheme Parameter FCM-II - FCM-IIM - FCM-IIXM
TransportStopperInX e.g.: -171
TransportStopperOutUsed YES or NO
TransportBeamLiftupX e.g.: -440
TransportNrOfBoards Number of boards, e.g.: 10
TransportIndexStep Up to 10 values. Allowed step
size 0 - 480, e.g.: 80 80 80
User Manual 4022 591 98247
164 PPS-Pro v8.2 05.07
Guidelines for using PPS-Pro
A.6.3.2 AX Index Schemes
For the AX type machines, the optimizer will calculate the required index
scheme (transport index settings). However, a user can override this by
defining his own required index schema.
For AX machines, following parameters can be modified:
TABLE 29 ALE Settings Attributes for AX
For the conveyor settings there are 3 possible options:
Auto mode
Semi-Auto mode
Manual mode
Normally use Auto mode. This means that NONE of following AX machine
production parameters are entered in the ALE file: TransportStopperInX,
TransportNrOfBoards, TransportIndexStep, TransportPanelPitch.
There might be situations you want to use Semi-Auto or Manual mode. This is
however not advised! For Semi-Auto the production parameters Transport
-
StopperInX and TransportPanelPitch must be specified in ALE. For Manual-
Auto the production parameters TransportStopperInX, TransportNrOf
-
Boards, and TransportIndexStep must be specified in ALE.
A.6.3.3 FCM-II – FCM-IIM – FCM-IIXM Production Parameters
For these machines the following parameters can be changed:
TABLE 30 ALE Settings Attributes for FCM-II, FCM-IIM and FCM-IIXM
The Mark parameters refer to the used shape definition file (vision file) on the
FCM machines.
Index Scheme Parameter AX
TransportStopperInX e.g. 0.036 (unit is meters!)
TransportNrOfBoards e.g. 24
TransportIndexStep e.g. 0 0.12 (unit is meters!)
TransportPanelPitch e.g. 0.12 0.12 (unit is meters!)
Parameter FCM-II - FCM-IIM - FCM-IIXM
BoardVision BMS+DFA or BMS or DFA or NO
BVM1Index YES or NO
PanelFidMark <number 1 – 255> e.g.: 1
BoardFidMark <number 1 – 255> e.g.: 2
PanelBadMark <number 1 – 255> e.g.: 3
BoardBadMark <number 1 – 255> e.g.: 4
VisionPosition 1 or 2 or 3 - For a WPM head this param-
eter has to be defined
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 165
Guidelines for using PPS-Pro
For the FCM-IIM and FCM-IIXM and additional set of parameters can be
changed by the user:
TABLE 31 ALE Settings Attributes for FCM-IIM & FCM-IIXM
NOTE: When DEFAULT is defined, the optimizer calculates the Reference Points. The
user can overrule this by defining these coordinates himself.
A.6.3.4 AX machine Production Parameters
For the AX base3 and base5 machines, following important parameters are
user definable:
TABLE 32 ALE Settings Attributes for AX
The LogicalPositionInLine defines the place of the machine in the line. Thus, if
an SMD line exists of AX machine – AX machine – AQ-1 machine, then the
logical position of the first AX machine is 1, of the second one is 2 and for the
Parameter FCM-IIM - FCM-IIXM
RightReferencePin DEFAULT or <value> e.g.: 123.45
LeftReferencePin DEFAULT or <value> e.g.: -34.29
BadMarkGrouping ON or OFF
FiducialGrouping ON or OFF
Parameter AX
BaseType BASE_3 or BASE_5
ProductionMode LOCAL or DISTRIBUTED
PanelFidMark
BoardFidMark
PartFidMark
<user definable> identifi-
ers for Panel, Circuit and
Part fiducials
BadMarkId <user definable>
LogicalPositionInLine 1 or 2 or 3 etc.
ProcessDataVersion 1.0
ControlSoftwareVersion 1.0
DoNotDuplicatePreassignment TRUE or FALSE
AlignmentMatrixPerCircuit TRUE or FALSE
MaxNoFiducialsPerAlignment-
Matrix
2 or 3
BadMarksRequireFiducials TRUE or FALSE
EnableNeighborhoodRestric-
tions
TRUE or FALSE
ProductionDirection RIGHT_TO_LEFT or
LEFT_TO_RIGHT