PPS-Pro GUI
Nozzle Number used
O2I2 1
O2I4 3
An example of a .nzl file for an FCM with 16 Laser Placement Modules is given
below:
Nozzle Setup Report
Machine: "FCM-II-16LAS"
PM Number PM Type Nozzle
1 LASER 4720
2 LASER 4720
3 LASER 4720
4 LASER 4720
5 LASER 4720
6 LASER 4720
7 LASER 4720
8 LASER 4720
9 LASER 4720
10 LASER No_Nozzle
11 LASER No_Nozzle
12 LASER 4730
13 LASER 4730
14 LASER 4730
15 LASER 4730
16 LASER 4730
Nozzle Number used
4720 9
No_Nozzle 2
4730 5
An example of an .nzl file for an AX Base 5 with 20 (Compact) Placement
Robots is given below:
Nozzle Setup Report
Machine: "M-AX5_20"
User Manual 4022 591 98247
84 PPS-Pro v8.2 05.07
PPS-Pro GUI
Head Number Head Type Nozzle
Head Number TEU Number Nozzle
1 1 L2, L3, L4, L5, L6, L7, L8
2 1 L2, L3, L4, L5, L6, L7, L8
3 1 L2, L3, L4, L5, L6, L7, L8
4 1 L2, L3, L4, L5, L6, L7, L8
5 1 L2, L3, L4, L5, L6, L7, L8
6 1 L2, L3, L4, L5, L6, L7, L8
7 1 L2, L3, L4, L5, L6, L7, L8
8 1 L2, L3, L4, L5, L6, L7, L8
9 1 L2, L3, L4, L5, L6, L7, L8
10 1 L2, L3, L4, L5, L6, L7, L8
11 1 L2, L3, L4, L5, L6, L7, L8
12 1 L2, L3, L4, L5, L6, L7, L8
13 1 L2, L3, L4, L5, L6, L7, L8
14 1 L2, L3, L4, L5, L6, L7, L8
15 1 L2, L3, L4, L5, L6, L7, L8
16 1 L2, L3, L4, L5, L6, L7, L8
17 1 L2, L3, L4, L5, L6, L7, L8
18 1 L2, L3, L4, L5, L6, L7, L8
19 1 L2, L3, L4, L5, L6, L7, L8
20 1 L2, L3, L4, L5, L6, L7, L8
Nozzle Number used
L5 20
L7 20
L2 20
L3 20
L6 20
L8 20
L4 20
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 85
PPS-Pro GUI
2.40Feeder setup information (.stp)
Feeder setup information on the machine level is provided in the <machine
name>.stp file. For combined product calculations this file contains the feeder
setup information for all calculated products. The count value zero means
that the part number is not used.
Below is an example of a .stp report for an AX:
Machine Name: M-AX5_20
Program Name: SomeProduct_Top.M-AX5_20.mdf
Date: 15 July 2003 11:26 AM
Bank Feeder Pick Pos. Part Number Package Count Fdr Type
-------------------------------------------------------------------------------------
1 1 492537 Tant6032 6 ITF2_08
1 3 1 175060 Tant6032 18 TTF_08
1 3 2 677904 C2518 16 TTF_08
1 7 502715 SOT89 20 ITF2_12
1 10 494896 SO8 4 ITF2_12
1 14 1 490267 R0603 0 TTF_08
1 14 2 502446 C1210 0 TTF_08
1 16 1 236024 C0603 0 TTF_08
Total 64
Example of a .stp report for an FCM Base 2 with 1 WVM:.
Machine Name: FCM-II-1WVM
Program Name: SomeProduct_Top.FCM-II-1WVM.mdf
Date: 20 April 2003 1:49 PM
Bank Feeder Part Number Count Feeder Type
-----------------------------------------------------------------------
1 101 R1206 1 ITF2_08
1 107 SO16 0 ITF2_16
2 201 R1206 2 ITF2_08
3 301 R1206 2 ITF2_08
4 401 R1206 2 ITF2_08
5 501 R1206 2 ITF2_08
6 601 R1206 2 ITF2_08