4OM-1610-002_w - 第191页
4OM-1610 3-44 3. Error IDs and Remedial Procedures : Chap.3 101 1-002 Error ID Error Name, Description, Cause, and Remedy 426201 positioning conveyor timeout Placement for input position was not completed within predeter…

4OM-1610
3-43
3. Error IDs and Remedial Procedures : Chap.3
1011-002
Error ID Error Name, Description, Cause, and Remedy
426108 Detection of positioning conveyor sensor
Stop sensor of input position was not detected before starting.
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thave
Error.
426109 Detection of positioning conveyor sensor
Decrease sensor of output position was detected before starting.
Thereis
anindeniteP.C.B.onOutputpositiondeceleratingsensor.Please
remove P.C.B..
42610a Detection of positioning conveyor sensor
Decrease sensor of output position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2.
There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
42610b Detection of positioning conveyor sensor
Stop sensor of output position was detected before starting.
The
reisanindeniteP.C.B.onOutputpositionstopsensor.PleaseremoveP.C.B..
42610c Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2.
There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
42610d Detection of positioning conveyor sensor
Decrease sensor of output position was detected after starting.
The
reisanindeniteP.C.B.onOutputpositionstopsensor.PleaseremoveP.C.B..
42610e Detection of positioning conveyor sensor
Decrease sensor of output position was not detected after starting.
-----
42610f Detection of positioning conveyor sensor
Stop sensor of output position was detected before starting.
The
reisanindeniteP.C.B.onOutputpositionstopsensor.PleaseremoveP.C.B..
426110 Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thave
Error.
426111 Detection of positioning conveyor sensor
P.C.B. on positioning conveyor was detected
Please remove P.C.B. from positioning conveyor.
426112 Detection of positioning conveyor sensor
NO P.C.B. on positioning conveyor
Conrmwhether
P.C.B.isnotdropping.ConrmwhetherSensorisnotbroken.
426113 Detection of positioning conveyor sensor
NO P.C.B. on positioning conveyor
PassingPCB
occurredduringsimultaneoustransfer.Pleaseconrmthatoutputis
running without problems.

4OM-1610
3-44
3. Error IDs and Remedial Procedures : Chap.3
1011-002
Error ID Error Name, Description, Cause, and Remedy
426201 positioning conveyor timeout
Placement for input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input conveyor to Input
positionor
isdropped.PleaseconrmfromInputtopositioningconveyor.
426202 positioning conveyor timeout
Output from input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.Please
conrmfrompositioningtoOutputconveyor.
426203 positioning conveyor timeout
Placement for output position was not completed within predetermined time.
P.C.B. inserted is place in Output position. There is a possibility of it fallen. Please
conrmfrom
InputtoPositioningconveyor.
426204 positioning conveyor timeout
Output from output position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.Please
conrmfrompositioningtoOutputconveyor.
426301 positioning conveyor Error
Error in positioning conveyor
-----
427101 Detection of Output conveyor sensor
Decrease sensor was detected before starting.
Thereis
anindeniteP.C.B.onOutputconveyor.Pleaseremoveit.
427102 Detection of Output conveyor sensor
Decrease sensor was not detected before starting the movement
P.C.B. to output is not found
1. Please put P.C.B. on Sensor
.
2. ThereisapossibilityofP.C.B.fallen.Conrmtheconveyorwidth.
427103 Detection of Output conveyor sensor
Stop sensor was detected before starting.
Thereis
anindeniteP.C.B..Pleaseremoveit.
427104 Detection of Output conveyor sensor
Stop sensor was not detected before starting.
Cannotnd
P.C.B.tooutput.
1. Is P.C.B. detected by sensor?
2. There is a possibility that P.C.B. is falling. Please check the width of conveyor.
427105 Detection of Output conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
Thereis
anindeniteP.C.B.onOutputconveyor.Pleaseremoveit.
427106 Detection of Output conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thave
Error.
427107 Detection of Output conveyor sensor
P.C.B. on stop sensor was detected after movement completion
Thereis
anindeniteP.C.B.onOutputconveyor.Pleaseremoveit.

4OM-1610
3-45
3. Error IDs and Remedial Procedures : Chap.3
1011-002
Error ID Error Name, Description, Cause, and Remedy
427108 Detection of Output conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thave
Error.
427109 Detection of Output conveyor sensor
P.C.B. on output conveyor was detected
Please remove P.C.B. from the conveyor
42710a Detection of Output conveyor sensor
P.C.B. on output conveyor was not detected
Please check whether P.C.B. is detected correctly.
Checkwhether
thesensordoesn’thaveError.
42710b Detection of Output conveyor sensor
Stop sensor is not passed during Output operation
The conveyor is stopped before P.C.B. goes through Sensor.
1. Conrm
outputmethod,transitionspeed,timersetting.
2. Check the connected cable.
42710c Detection of Output conveyor sensor
Disengaged P.C.B. of output conveyor
P.C.B. was removed from Output Conveyor.
Please check the state of it if removing P.C.B. does not happen intentionally.
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the above conveyor.
427202 Output conveyor timeout
Output was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the transition with Output Machine.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 Middle Conveyor Error
Time-out in Placement from Input Machine.
PCB is not placed in Device. Please check Middle Conveyor.
1.
Whether Emergency stop is pressed
2. Whether Safety Cover is open
3.
Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 Middle Conveyor Error
Time-out in Output for Output Machine.
PCB is not outputted from Device. Please check Middle conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3.
Whether Breaker is falling down