1.4 Maintenance Method 1.4.1 Air Source (1) Purging Place a container , etc., under a filter case and press the button lo- cated at the lower section of the filter case to drain the wastewater (dirty water , sometimes mi…

100%1 / 409
0511-001 1-47-1 AIL01ETRP
1.3 Maintenance Spots
(28) Exhaust Cleaner
Element 6M12
Every 6 Months Replacement/Cleaning
The grease supplied to the cam constraining
cylinder collects in the oil case.
Detach the oil case and remove the nut to
replace the element with a new one.
Wipe off the grease that has accumulated in
the oil case with a rag.
Refer to "1.4.14 Replacement of Exhaust
Cleaner Element" for how to replace the
element.
Nut
Oil Case
Although it is recommended that the
element should be replaced or cleaned
every 6 months, the element must be
replaced or cleaned whenever grease
has supplied to the cam constraining
cylinder in the placement U/D section
(21) six times so far regardless of
whether six months has elapsed or not
after the previous replacement or
cleaning.
Note
Fig. 4A59
1.4 Maintenance Method
1.4.1 Air Source
(1) Purging
Place a container, etc., under a filter case and press the button lo-
cated at the lower section of the filter case to drain the wastewater
(dirty water, sometimes mixed with oil) from the case.
Fig. 4A60
(2) Filter Detachment and Attachment
Turn the knob until the upturned equilateral triangles match each
other as shown in the figure above and pull down the case. The
case can easily be detached. The case can also be locked by match-
ing the upturned and downturned equilateral triangles.
To detach the filter, remove the outer case and turn the inner filter
counterclockwise.
Follow the reverse procedure to attach the filter.
(3) Filter Cleaning
Use an air gun to clean the filters once in three months or whenever
they get dirty.
0305-001 1-48
AIL01ETRP
1.4 Maintenance Method
1.4.2 Filter Replacement of Head Section
(1) Detachment of Filter Holder
Pull out the filter holder forward.
Fig. 4A61
(2) Replacement of Filters
Detach two filters sideways and replace them with new ones.
Fig. 4A62
(3) Attachment of Filter Holder
Direct Cut-Off Side D upward and insert the filter holder fully until it
stops.
0305-001 1-49 AIL01ETRP
1.4 Maintenance Method