0305-001 1-80 AIL01ETRP 1.4 Maintenance Method (25-3) Press the [F1] and [F2] buttons (entitled "FEEDER READY"). Press the [ON] button (entitled "MOVE"). In two seconds, press the [ENABLE] button on t…

100%1 / 409
0305-001 1-79 AIL01ETRP
1.4 Maintenance Method
(25) Confirm whether the reference mark on the linear scale can be
detected or not.
(25-1) When the "Ref Mark Detect" tab is pressed in the "Fdr Crg"
tab sheet, the following tab sheet appears.
Fig. 4A85-11 "Ref Mark Detect" Tab Sheet
(25-2) When the [Start Reference Mark Detection] button is pressed
in the "Ref Mark Detect" tab sheet, the following sheet ap-
pears.
Fig. 4A85-12
0305-001 1-80 AIL01ETRP
1.4 Maintenance Method
(25-3) Press the [F1] and [F2] buttons (entitled "FEEDER READY").
Press the [ON] button (entitled "MOVE"). In two seconds,
press the [ENABLE] button on the operation panel. Feeder
Carriage #2 moves to the F1 side and the following sheet
appears.
Fig. 4A85-13
(25-4) Press the [Next] button.
When the [ENABLE] button on the operation panel is pressed
in two seconds after the [ON] button (entitled "MOVE"), "2.
Move F2 Axis to Ref Mark (-)" is executed.
Follow the same procedure repeatedly and confirm that the
reference marks (Operation Procedure: 3 through 5) are
detected.
0511-002 1-81 AIL01ETRP
1.4 Maintenance Method
1.4.10 Cleaning of Linear Scale Section
To avoid any malfunction of the feeder carriages, the linear scales
and the linear scale encoder heads must be cleaned every three
months or whenever the linear guides are lubricated.
Also, make the reference mark detection and confirm the perfor-
mance of the machine.
Cleaning of Linear Scales
(1) When the "Linear Scale Clean" tab is pressed in the "Fdr Crg" tab
sheet, the following tab sheet appears.
Fig. 4A86-1 "Linear Scale Clean" Tab Sheet