Check Code Display Section A Display Section B 801701 T each Nozzle Nozzle Down Error .(L) Bypass 801702 T each Nozzle Nozzle Down Error .(H) Bypass 801703 T each Nozzle Recognition T each Error . Bypass 801704 T each No…

100%1 / 409
1.3 Machine lnformation
0511-002 2-18 AIL01ETRP
Check Code Display Section A Display Section
801208 Stat Auto Head Unselected Nozzle Drop.
Recovery
801209 Stat Auto Head Component output error(Pickup error) is detected by nozzle level
Recovery was position. ;Nozzle posture detection
80120a Stat Auto Head The selected nozzle was not at position. ;Nozzle posture detec-
Recovery tion
80120b Stat Auto Head Component output error(Others) is detected by nozzle level was
Recovery position. ;Nozzle posture detection
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
801301 Pickup Position Feedback value out of range. Please check feeder.
Feedback
801401 Pickup Level Data Calculated data out of range. Please check library data and offset
data.
801402 Placement Level Calculated data out of range. Please check library data and offset
Data data.
801501 Feeder Index Production operation was interrupted in the middle of feeder index
Position operation. Please check a position.
801502 Feeder Index The feeder carriage was returned to the home position in the middle
Position of feeder index operation.
Please check a feeder index position.
801601 Product Restart Restart production with semi-auto(after specified step) mode.
801602 Product Restart Restart production with warm start mode.
801603 Product Restart Restart production with warm start mode after EMER stop. Ma-
chine will stop after placement complete. Please confirm PCB af-
terward.
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
Check Code Display Section A Display Section B
801701 Teach Nozzle Nozzle Down Error.(L)
Bypass
801702 Teach Nozzle Nozzle Down Error.(H)
Bypass
801703 Teach Nozzle Recognition Teach Error.
Bypass
801704 Teach Nozzle Teach Error Data.
Bypass
801705 Teach Nozzle Lighting Check.
Bypass
801706 Teach Nozzle Nozzle Level.
Bypass
801707 Teach Nozzle Nozzle Drop
Bypass
801708 Teach Nozzle Dummy Nozzle.
Bypass
801709 Teach Nozzle Manual Bypass.
Bypass
80170a Teach Nozzle Nozzle Change Error.(Cam lock action)
Bypass
80170b Teach Nozzle Nozzle Change Error.(Cam Free action)
Bypass
80170c Teach Nozzle Cam Origin Error.
Bypass
80170d Teach Nozzle Nozzle Teach Error.
Bypass
80170e Teach Nozzle Nozzle Posture Detection
Bypass
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
1.3 Machine lnformation
0511-002 2-19 AIL01ETRP
Check Code Display Section A Display Section B
801801 Teach Head Bypass Communication Error.
801802 Teach Head Bypass Head Origin.
801803 Teach Head Bypass Overtime Head Origin Return.
801804 Teach Head Bypass Unselected Nozzle Drop.
801805 Teach Head Bypass Dummy Nozzle.
801806 Teach Head Bypass Manual Bypass.
801807 Teach Head Bypass Alarm Error.
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
801901 Nozzle Adjustment Nozzle UP&Down Action is not Available.
801902 Nozzle Adjustment Communication error.
801903 Nozzle Adjustment Confirm of the defective of Nozzle exchange.(Tact)
(Contents) Self-Diagnostics Error Message
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
801a01 Warning Operation Product started by RUN MODE "PASS" Operation.
801a02 Warning Operation The P.C.B. before component placing was conveyed from X/Y
table.
801a03 Warning Operation The P.C.B. in the middle of component placing was conveyed from
X/Y table.
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
1.3 Machine lnformation