4OM-1003-007 - 第276页

(10 X/Y Chute Width) Error ID Item Description 100101 X/Y Chute Width Origin Output signal from the pulse motor driver was not detected. 100102 X/Y Chute Width Origin Feedback value is indefinite. 100103 X/Y Chute Width …

100%1 / 409
0511-001 2-84-1 AIL01ETRP
Error ID Item Description
0f0801 Transfer Interlock Transfer unable to work because X/Y table was not at origin.
0f0802 Transfer Interlock Transfer unable to work because X/Y table was not running.
0f0803 Transfer Interlock Transfer unable to work because input conveyor was not
running forward.
0f0804 Transfer Interlock Transfer unable to work because input conveyor was not run-
ning backward.
0f0805 Transfer Interlock Transfer unable to work because output conveyor was not
running.
0f0806 Transfer Interlock X/Y table chute was not detected (lower position) while mov-
ing table.; BPH61/BPH70
0f0807 Transfer Interlock Upper limit of x/y table chute was detected. (lower position);
BPH60 e/nr
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0f0901 Transfer Data DDMC data communication timeout
Communication Error
0f0902 Transfer Data DDMC board communication error
Communication Error
0f0903 Transfer Data Data checksum error
Communication Error
0f0904 Transfer Data No answer
Communication Error
0f0905 Transfer Data Busy
Communication Error
0f0906 Transfer Data No command
Communication Error
0f0907 Transfer Data No answer from PMD
Communication Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
(10 X/Y Chute Width)
Error ID Item Description
100101 X/Y Chute Width Origin Output signal from the pulse motor driver was not detected.
100102 X/Y Chute Width Origin Feedback value is indefinite.
100103 X/Y Chute Width Origin The table-y is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
100201 X/Y Chute Width Timing Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
100301 X/Y Chute Width Data The driver data was detected outside of the possible range.
(Cause 1) The "Product Change" tab sheet was opened and the manual axis operation was
performed to widen the width from the origin position. Or, the manual axis opera-
tion was performed to make the width narrower.
(Remedy 1) Cancel the error display with the [RETURN] button and perform the manual axis
operation in the correct direction.
100401 X/Y Chute Width Limit (+) Limit error has been detected. ;BPH73 E/NR
100402 X/Y Chute Width Limit (-) Limit error has been detected. ;BPH74 E/NR
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Remedy 1) Turn off the power supply and move the conveyor width with the manual knob for
easier operation. Re-attach the light shield plate or the sensor securely (remove
the looseness).
pen the "Product Change" tab sheet and confirm that the chute width can be
changed as specified.
If necessary, correct the "Clearance" data for the chute width.
(Remedy 2) Wipe off dirt on the sensor and zero the chute width.
0511-002 2-85 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
100501 X/Y Chute Wd. Chute Up-Down The chute wd. Has not descended smoothly resulting in
an overtime alarm. ; (BPH61) OFF
100502 X/Y Chute Wd. Chute Up-Down The chute wd. Has not ascended smoothly resulting in
an overtime alarm. ; (BPH60)
100503 X/Y Chute Wd. Chute Up-Down The chute wd. Has not descended by P.C.B. detected.
(bph89/bph92) on
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
100601 X/Y Chute Wd. Communication The controller can not run.
100602 X/Y Chute Wd. Communication Controller interior is out of order.
100603 X/Y Chute Wd. Communication Controller in communication error condition.
100604 X/Y Chute Wd. Communication Controller incomplete resulting in an overtime alarm.
100701 X/Y Chute Wd. Alarm Task has not been completed unable to continue.
100702 X/Y Chute Wd. Alarm Another task system is interlock occured.
100703 X/Y Chute Wd. Alarm Controller in alarm error condition.(Task has Complete)
(Cause 1) Self-Diagnostics Error Message.
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
(Remedy 2) Check the stabilization power supply unit.
0511-002 2-86 AIL01ETRP
3.3 Error IDs and Remedial Procedures