(1 1 L Conveyor Width) Error ID Item Description 1 10101 L CONVEYOR WIDTH ORIGIN OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER W AS NOT DETECTED. 1 10102 L CONVEYOR WIDTH ORIGIN FEEDBACK V ALUE IS INDEFINITE. 1 10103 L CONVE…

100%1 / 409
Error ID Item Description
100501 X/Y Chute Wd. Chute Up-Down The chute wd. Has not descended smoothly resulting in
an overtime alarm. ; (BPH61) OFF
100502 X/Y Chute Wd. Chute Up-Down The chute wd. Has not ascended smoothly resulting in
an overtime alarm. ; (BPH60)
100503 X/Y Chute Wd. Chute Up-Down The chute wd. Has not descended by P.C.B. detected.
(bph89/bph92) on
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
100601 X/Y Chute Wd. Communication The controller can not run.
100602 X/Y Chute Wd. Communication Controller interior is out of order.
100603 X/Y Chute Wd. Communication Controller in communication error condition.
100604 X/Y Chute Wd. Communication Controller incomplete resulting in an overtime alarm.
100701 X/Y Chute Wd. Alarm Task has not been completed unable to continue.
100702 X/Y Chute Wd. Alarm Another task system is interlock occured.
100703 X/Y Chute Wd. Alarm Controller in alarm error condition.(Task has Complete)
(Cause 1) Self-Diagnostics Error Message.
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
(Remedy 2) Check the stabilization power supply unit.
0511-002 2-86 AIL01ETRP
3.3 Error IDs and Remedial Procedures
(11 L Conveyor Width)
Error ID Item Description
110101 L CONVEYOR WIDTH ORIGIN OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER
WAS NOT DETECTED.
110102 L CONVEYOR WIDTH ORIGIN FEEDBACK VALUE IS INDEFINITE.
110103 L CONVEYOR WIDTH ORIGIN L COVEYOR WIDTH IS NOT AT ORIGIN.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
110201 L CONVEYOR WIDTH TIMING TASK HAS NOT BEEN COMPLETED UNABLE TO
CONTINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
110301 L CONVEYOR WIDTH DATA THE DRIVER DATA WAS DETECTED OUTSIDE OF
THE POSSIBLE RANGE.
(Cause 1) The "Product Change" tab sheet was opened and the manual axis operation was
performed to widen the width from the origin position. Or, the manual axis opera-
tion was performed to make the width narrower.
(Remedy 1) Cancel the error display with the [RETURN] button and perform the manual axis
operation in the correct direction.
110401 L CONVEYOR WIDTH LIMIT LIMIT (+) ERROR HAS BEEN DETECTED. ; BPH77 E/NR
110402 L CONVEYOR WIDTH LIMIT LIMIT (−) ERROR HAS BEEN DETECTED. ; BPH78 E/NR
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 3) The sensor is defective.
(Remedy 1) Turn off the power supply and move the conveyor width with the manual knob for
easier operation. Re-attach the light shield plate or the sensor securely (remove
the looseness).
Re-supply power to the machine and zero the L conveyor width.
Open the "Product Change" tab sheet and confirm that the L conveyor width can
be changed as specified.
If necessary, correct the "Clearance" data for the conveyor width.
(Remedy 2) Wipe off dirt on the sensor and zero the L conveyor again.
(Remedy 3) It is required to replace the sensor.
Contact our service personnel for details.
0511-002 2-87 AIL01ETRP
3.3 Error IDs and Remedial Procedures
(12 R Conveyor Width)
Error ID Item Description
120101 R CONVEYOR WIDTH ORIGIN OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER
WAS NOT DETECTED.
120102 R CONVEYOR WIDTH ORIGIN FEEDBACK VALUE IS INDEFINITE.
120103 R CONVEYOR WIDTH ORIGIN R CONVEYOR WIDTH IS NOT AT ORIGIN.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120201 R CONVEYOR WIDTH TIMING TASK HAS NOT BEEN COMPLETED UNABLE TO
CONTINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120301 R CONVEYOR WIDTH DATA THE DRIVER DATA WAS DETECTED OUTSIDE OF THE
POSSIBLE RANGE.
(Cause 1) The "Product Change" tab sheet was opened and the manual axis operation was
performed to widen the width from the origin position. Or, the manual axis opera-
tion was performed to make the width narrower.
(Remedy 1) Cancel the error display with the [RETURN] button and perform the manual axis
operation in the correct direction.
120401 R CONVEYOR WIDTH LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH79 E/NR
120402 R CONVEYOR WIDTH LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH80 E/NR
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Remedy 1) Turn off the power supply and move the conveyor width with the manual knob for
easier operation. Re-attach the light shield plate or the sensor securely (remove
the looseness).
Re-supply power to the machine and zero the L conveyor width.
Open the "Product Change" tab sheet and confirm that the L conveyor width can
be changed as specified.
If necessary, correct the "Clearance" data for the conveyor width.
(Remedy 2) Wipe off dirt on the sensor and zero the L conveyor again.
0511-002 2-88 AIL01ETRP
3.3 Error IDs and Remedial Procedures