Error ID Item Description 410601 Component Data Available nozzle is not found. "Check the Nozzle layout data or Nozzle skip conditon." 410701 Nozzle T ype (Cause 1) A correct nozzle may not be attached or the a…

100%1 / 409
(41 Data)
Error ID Item Description
410101 PLACEMENT NOZZLE APPROPRIATE NOZZLE MISSING.
"Check the Nozzle layout data or Nozzle skip conditon."
(Cause 1) A nozzle different from the nozzle-related data is attached.
(Remedy 1) Check the attached nozzle and the "Nozzle Data" window (described in "4. Nozzle
Data" in "Section 5 (Vol. 3: Programming and Machine Data)" and reset the ma-
chine to its normal condition.
410201 Alternate Mode Available fdr.carriage is not found.
(Cause 1) A wrong parameter is set in the "Alternate" tab sheet.
(Remedy 1) Check the carriage to be used and correct the wrong parameter if any.
410301 Current Pattern Program
No Exist
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform a program change operation.
When the program change operation cannot be performed, contact our service
personnel.
410401 Component Cannot refer to component data.
(Cause 1) A mistake is found in the placement feeder location data of the pattern program
data.
(Remedy 1) Check the placement feeder location data. If necessary, correct the mistake.
410501 Placement Data Already placed
410502 Placement Data Placement step missing. Start and recovery with WARM
START.
410503 Placement Data Placement Complete step missing. Start and recovery with
Manual or Warm START.(Cycle stop mode)
410504 Placement Data Placement complete step missing. Check the P.C.B.
now.(Running cancel mode.)
410505 Placement Data Placement complete step missing. Check the P.C.B. (Run
ning countinue mode.)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Follow the described instructions and reset the machine to its normal condition.
0511-002 2-95 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
410601 Component Data Available nozzle is not found.
"Check the Nozzle layout data or Nozzle skip conditon."
410701 Nozzle Type
(Cause 1)A correct nozzle may not be attached or the attached nozzle may not conform to the
placement head/nozzle data and the nozzle type data.
(Remedy 1) Check the nozzle attached to the head of the machine.
Refer to the "4. Nozzle Data" in "Section 5 (Vol. 3: Programming and Machine
Data)" and check the placement head/nozzle data and the nozzle type data.
410801 Current Pattern Program
No Exist
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform a program change operation.
When the program change operation cannot be performed, contact our service
personnel.
410901 PEC Inspect Data Overflow P.E.C. inspect data count.
410a01 Pattern Program Data 'E' is input to the control command of P data.
It is not possible to use it at the R&C bad mark function.
(Cause 1) The pattern program data is wrong.
(Remedy 1) Create a correct pattern program.
0511-002 2-96 AIL01ETRP
3.3 Error IDs and Remedial Procedures
3.3 Error IDs and Remedial Procedures
0511-003 2-97 AIL01ETRP
(42 Conveyor)
Error ID Item Description
420101 Input Buffer Cnvr. Overtime P.C.B. from inp. machine was not received.
420102 Input Buffer Cnvr. Overtime P.C.B. on inp.buffer cnvr. was not able to move to its outlet.
(Cause 1) The P.C.B. is trapped on the conveyor.
(Cause 2) An operator removed the P.C.B. in the middle of transfer.
(Remedy 1) The conveyor width may not be adjusted correctly or the P.C.B. size may be
different.
Readjust the conveyor width or confirm if the P.C.B. size is proper or not.
(Remedy 2) Place the P.C.B. back in position and re-start the automatic operation.
420201 Input Cnvr. P.C.B. Overtime P.C.B. on input cnvr. was not able to move to its outlet.
(Cause 1) The light emitted from the P.C.B. detection photosensor on the L2 conveyor is
received or not.
Dirt may have adhered to the sensor.
(Cause 2) The P.C.B. transfer detection photosensor on the L2 conveyor is defective.
(Remedy 1) Check if the light emitted from the P.C.B. detection photosensor can be received
or not.
(Remedy 2) Contact our service personnel for details.
420202 Input Cnvr. P.C.B. Overtime P.C.B. from inp. buffer cnvr. was not received.
(Cause 1) The light emitted from the P.C.B. detection photosensor on the L1 conveyor is
received or not.
Dirt may have adhered to the sensor.
(Cause 2) The set value for Input Output Conveyor Timer 2 or Output Conveyor Timer 2 has
exceeded the range of setting.
(Cause 3) The P.C.B. transfer detection photosensor on the L1 conveyor is defective.
(Remedy 1) Check if the light emitted from the P.C.B. detection photosensor on the L1 con-
veyor can be received or not.
(Remedy 2) Correct the set value for Input Conveyor Timer 2 or Output Conveyor Timer 2.
(Remedy 3) Contact our service personnel for details.
420203 Input Cnvr. P.C.B. Overtime P.C.B. on X/Y table chute was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.