Error ID Item Description 420301 Output Cnvr . Overtime P .C.B. to output machine was not transferred. 420302 Output Cnvr . Overtime P .C.B. on output cnvr . was not able to move to its outlet. (Cause 1) Self-Diagnostics…

3.3 Error IDs and Remedial Procedures
0511-003 2-97 AIL01ETRP
(42 Conveyor)
Error ID Item Description
420101 Input Buffer Cnvr. Overtime P.C.B. from inp. machine was not received.
420102 Input Buffer Cnvr. Overtime P.C.B. on inp.buffer cnvr. was not able to move to its outlet.
(Cause 1) The P.C.B. is trapped on the conveyor.
(Cause 2) An operator removed the P.C.B. in the middle of transfer.
(Remedy 1) The conveyor width may not be adjusted correctly or the P.C.B. size may be
different.
Readjust the conveyor width or confirm if the P.C.B. size is proper or not.
(Remedy 2) Place the P.C.B. back in position and re-start the automatic operation.
420201 Input Cnvr. P.C.B. Overtime P.C.B. on input cnvr. was not able to move to its outlet.
(Cause 1) The light emitted from the P.C.B. detection photosensor on the L2 conveyor is
received or not.
Dirt may have adhered to the sensor.
(Cause 2) The P.C.B. transfer detection photosensor on the L2 conveyor is defective.
(Remedy 1) Check if the light emitted from the P.C.B. detection photosensor can be received
or not.
(Remedy 2) Contact our service personnel for details.
420202 Input Cnvr. P.C.B. Overtime P.C.B. from inp. buffer cnvr. was not received.
(Cause 1) The light emitted from the P.C.B. detection photosensor on the L1 conveyor is
received or not.
Dirt may have adhered to the sensor.
(Cause 2) The set value for Input Output Conveyor Timer 2 or Output Conveyor Timer 2 has
exceeded the range of setting.
(Cause 3) The P.C.B. transfer detection photosensor on the L1 conveyor is defective.
(Remedy 1) Check if the light emitted from the P.C.B. detection photosensor on the L1 con-
veyor can be received or not.
(Remedy 2) Correct the set value for Input Conveyor Timer 2 or Output Conveyor Timer 2.
(Remedy 3) Contact our service personnel for details.
420203 Input Cnvr. P.C.B. Overtime P.C.B. on X/Y table chute was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.

Error ID Item Description
420301 Output Cnvr. Overtime P.C.B. to output machine was not transferred.
420302 Output Cnvr. Overtime P.C.B. on output cnvr. was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
420401 Input Buffer Cnvr. Inp. machine send sig. turned off before P.C.B. reached in-
P.C.B. Detection put cnvr.
420402 Input Buffer Cnvr. P.C.B.`s were at inlet and outlet of input buffer cnvr.
P.C.B. Detection
(Cause 1) The P.C.B. transfer signal from the input machine was turned off before the P.C.B.
was detected by the P.C.B. detection photosensor at the input conveyor outlet side.
There are two P.C.B.’s on the input conveyor.
(Remedy 1) Adjust the position of the P.C.B. detection photosensor (outlet).
The P.C.B. detection photosensor (outlet) is defective and required to be replaced
with a new one.
420501 Input Cnvr. P.C.B. Detection The sensor position is illegal setting.
420502 Input Cnvr. P.C.B. Detection P.C.B.`s were at inlet and outlet of input cnvr.
420503 Input Cnvr. P.C.B. Detection P.C.B. on inp. cnvr. was not able to move to its transfer ac-
tion.
(Cause 1) The P.C.B. was carried back to the P.C.B. transfer claw during automatic opera-
tion. Or, the P.C.B. is shifted out of the coverage of the P.C.B. detection photosensor.
• The P.C.B. detection photosensor is attached to a wrong position.
• The X value of "P.C.B. SIZE" has exceeded the range of setting.
(Remedy 1) Press the [RETURN] button to cancel the error display and zero the P.C.B. trans-
fer.
Adjust the position of the P.C.B. detection photosensor.
Set the correct X value for "P.C.B. SIZE".
420601 Output Cnvr. P.C.B. Detection Out. machine work req. sig. turned off before P.C.B. trns.act
completed.
420602 Output Cnvr. P.C.B. Detection P.C.B. on output cnvr. was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0403-002 2-98 AIL01ETRP
3.3 Error IDs and Remedial Procedures

(43 Self-Diagnostics 1)
Error ID Item Description
430101 Nozzle Change Nozzle change action error. (DD-head camfree position)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430207 NOZZLE POSITION Nozzle posture system alarm signal was detected.
430208 NOZZLE POSITION Communication error in nozzle posture system.
(Cause 1) The optical beam was not set in the "E/R" or the "E/NR" condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received)
The sensor may be defective.
(Remedy 1) Press the [RETURN] button to cancel the error display and check that no dirt
adheres to the sensor.
430209 NOZZLE POSITION The selected nozzle was erroneously positioned. ;Nozzle
posture detection
(Cause 1) The selected nozzle moved down, passing over the low level at Station #10.
Self-Diagnostics Error Message.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
43020a NOZZLE POSITION The selected nozzle level was not at high position. ;Nozzle
posture detection
43020b NOZZLE POSITION The selected nozzle level was not at low position. ;Nozzle
posture detection
(Cause 1) When the nozzle change operation was completed at Station #10, the nozzle detec-
tion sensor could not detect the normal level (High/Low Level) of the nozzle.
(Defective Nozzle Sliding Movement)
(Remedy 1) Check the contents of the error and re-start the operation.
When the error still occurs frequently after the operation is re-started, adjust the
object head and check the sliding movement.
Refer to "1.4.5 Disassembly, Cleaning, and Lubrication of Miniature Stroke Bear-
ing" in "Section 1" for the adjustment.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-99 AIL01ETRP
3.3 Error IDs and Remedial Procedures