4OM-1003-007 - 第310页
(48 Component Recognition) Error ID ltem Description 480101 DEVICE INSPECT Failed in Issuing the Lighting Selection Command. 480102 DEVICE INSPECT Error Response of Lighting Selection Command! 480103 DEVICE INSPECT Delay…

(46 P.E.C. Recognition)
Error ID ltem Description
460101 PEC Inspect P.E.C. Mark #1 (Global)
460201 PEC Inspect P.E.C. Mark #2 (Global)
460301 PEC Inspect P.E.C. Mark #3 (Global)
460401 PEC Inspect P.E.C. Mark #1 (Image)
460501 PEC Inspect P.E.C. Mark #2 (Image)
460601 PEC Inspect P.E.C. Mark #3 (Image)
460701 PEC Inspect P.E.C. Mark #1 (Local)
460801 PEC Inspect P.E.C. Mark #2 (Local)
460901 PEC Inspect P.E.C. Mark #3 (Local)
460a01 PEC Inspect P.E.C. Recognition Test
460b01 PEC Inspect P.E.C. Recog. Light Teach
460c01 PEC Inspect Error Response of P.E.C. Recog. Command
Refer to "4.3.3 P.E.C. Recognition Errors" for "(Cause 1)" and "(Remedy 1)".
460e01 PEC Inspect (Re_trial) P.C.B. position gap was detected at P.E.C. re-trial check
(Cause 1) Self-Diagnostics Error Message
The result of the P.E.C. re-trial check operation was out of the specified tolerance
range.
(Remedy 1) Check the results of the detection in the exclusive window. After that, check how
the P.C.B. is positioned on the X/Y table.
3.3 Error IDs and Remedial Procedures
0511-003 2-111 AIL01ETRP

(48 Component Recognition)
Error ID ltem Description
480101 DEVICE INSPECT Failed in Issuing the Lighting Selection Command.
480102 DEVICE INSPECT Error Response of Lighting Selection Command!
480103 DEVICE INSPECT Delayed Response of Lighting Selection Command!
480104 DEVICE INSPECT Failed in Issuing the Image Capture Command.
480105 DEVICE INSPECT Error Response of Image Capture Command!
480106 DEVICE INSPECT Failed in Issuing the Recognition Command.
480107 DEVICE INSPECT Delayed Response of Image Capture Command!
480108 DEVICE INSPECT Error Response of Recognition Command!
480109 DEVICE INSPECT Error Response of Recognition Command (Delayed Recogni
tion)!
48010a DEVICE INSPECT Error in Recognition-Related Data Transfer!
48010b DEVICE INSPECT Failed in Issuing the Recognition Interrupt Command.
48010c DEVICE INSPECT Error Response of Recognition Interrupt Command!
48010d DEVICE INSPECT Time-Out of Recognition Interrupt Processing
48010e DEVICE INSPECT Time-Out of Lighting Selection Processing
48010f DEVICE INSPECT Time-Out of Recognition ON Response
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
480110 DEVICE INSPECT No Candidate for Recog Image Save!
(Cause 1)There is no objective data for image saving.
Continue the operation until the objective recognition image data is generated and
saved.
(Remedy 1) (1) Follow the automatic operation setup procedure to set the recognition image
save function again.
(2) Resume the operation and wait until the objective requirements for image
saving are gathered.
0511-003 2-112 AIL01ETRP
3.3 Error IDs and Remedial Procedures

(49 Control P.C.B.)
Error ID ltem Description
490101 CPU1 Board Error in an internal communication interruption program.
Please turn off a breaker.
490102 CPU1 Board Error in an internal data reception program. Please turn off a
breaker.
490103 CPU1 Board Error in an internal data transmitting program. Please turn
off a breaker.
490201 CPU2 Board
490202 CPU2 Board Memory allocation error.
490203 CPU2 Board System error occurred.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
490301 Recognition Board Recognition board was not detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
490401 HLSC2 Board HLSC2 board was not detected.
490402 HLSC2 Board H1 board was not detected.
490403 HLSC2 Board System error occurred.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-113 AIL01ETRP