4OM-1003-007 - 第324页
051 1-001 2-124-1 AIL01ETRP Error ID ltem Description 500b01 Cancel Recovery On Collect component if necessary . 500b02 Cancel Recovery On Pick-up Sequence Cancel. Collect component if necessary . 500b03 Cancel Recovery …

Error ID ltem Description
500701 Alternate Feeder Disable
(Cause 1) The machine stopped running because the linear measure detection sensor de-
tected the "Component Thickness Error (Sensor)" error continuously.
Ref.: When "9" is set in the "2” text box of "Error process” in the component library
data, it means that a pick-up error occurred continuously 9 times on the
same feeder No.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check "Step" and "Feeder No." where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled "ZERO"). After that, check
the following items related to the pertinent feeder No.
• Check if the tape feeder is loaded with correct components.
• Check the selected components and the component library data.
If wrong parameters are set in the component library data, correct them.
Note: Check the parameter set as component thickness check data in
the "CMPNT CARRIAGE DATA EDIT" window.
(3) After taking the required countermeasures, re-start the production.
500801 Comp. Pickup Diff.(recog.)
500901 Comp. Reverse(recog.)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
500a01 Alternate Feeder Disable "Enable alt. And press [READY] button.
Then, press [START] to re-start."
(Cause 1) A component shortage error has occurred on all tape feeders in the group being
used as an objective one for the feeder alternate mode.
(Remedy 1) Press the [RETURN] button to cancel the error display. After that, set "Enable
Exist" for the feeders in the “Alternate Fdr. Mode" group box of the “Alternate"
tab sheet. (Operation Sequence: "OPN. MODE" Window (Submenu) Æ "Alter-
nate" Tab Sheet)
0511-003 2-124 AIL01ETRP
3.3 Error IDs and Remedial Procedures

0511-001 2-124-1 AIL01ETRP
Error ID ltem Description
500b01 Cancel Recovery On Collect component if necessary.
500b02 Cancel Recovery On Pick-up Sequence Cancel.
Collect component if necessary.
500b03 Cancel Recovery On Component Output was check sequence mode.
Collect component if necessary.
500b04 Cancel Recovery On Nozzle Down Error(Low).
Collect component if necessary.
500b05 Cancel Recovery On Nozzle Down Error(High).
Collect component if necessary.
500b06 Cancel Recovery On Selected Nozzle Position Error.
Collect component if necessary.
500b07 Cancel Recovery On Unselected Nozzle Drop.
Collect component if necessary.
500b08 Cancel Recovery On Cam Positon Return Error.
Collect component if necessary.
500b09 Cancel Recovery On Nozzle Change Error.
Collect component if necessary.
500b0a Cancel Recovery On The nozzle change lever was not activated.
Collect component if necessary.
500b0b Cancel Recovery On The nozzle change/return lever was not activated.
Collect component if necessary.
500b0c Cancel Recovery On Pick-up Y-position Error.
Collect component if necessary.
500b0d Cancel Recovery On Pick-up Error.
Collect component if necessary.
500b0e Cancel Recovery On The selected nozzle was not at position. ;Nozzle posture
detection. Collect component if necessary.
500b0f Cancel Recovery On Component backtrack or Component output is detected.
;Nozzle posture detection. Collect component if necessary.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
500c01 Auto Recovery Pause "Attach the new comp. And press [READY].
Then, press [START] button to re-start."
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.

0511-003 2-125 AIL01ETRP
3.3 Error IDs and Remedial Procedures
3.3.3 Teaching Errors
(60 Nozzle Position)
Error ID ltem Description
600101 Nozzle Recog. Recognition Error Code.
Ref.: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
600201 Nozzle Bypass Nozzle Down Error. (L)
600202 Nozzle Bypass Nozzle Down Error. (H)
600203 Nozzle Bypass Recognition Teach Error.
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
600204 Nozzle Bypass Teach Error Data.
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
600205 Nozzle Bypass Lighting Check.
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.