Error ID ltem Description 620301 Head Skip Communication Error 620302 Head Skip Head Origin 620303 Head Skip Overtime Head Origin Return 620304 Head Skip Unselected Nozzle Drop 620305 Head Skip Dummy Nozzle 620306 Head S…

Error ID ltem Description
620206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
620207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
620208 Nozzle Bypass Dummy Nozzle
620209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the “Head/Noz. Bypass” tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
62020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
62020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
62020c Nozzle Bypass Cam Origin Error.
62020d Nozzle Bypass Nozzle Teach Error.
62020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-134 AIL01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
620301 Head Skip Communication Error
620302 Head Skip Head Origin
620303 Head Skip Overtime Head Origin Return
620304 Head Skip Unselected Nozzle Drop
620305 Head Skip Dummy Nozzle
620306 Head Skip Manual Bypass
620307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
620401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
620402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
620403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
620404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
620501 Master Head Offset Linear Measure System Was At High Position.
620502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-135 AIL01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
620601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
620701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
620702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
620801 Recog. Data Teach Recognition Error Code.
620901 Trash Teach Error Code. Recognition Error Code.
Note: Refer to "4. Troubleshooting on Recognition System" for details.
0305-001 2-136 AIL01ETRP
3.3 Error IDs and Remedial Procedures