4OM-1003-007 - 第340页
051 1-002 2-140 AIL01ETRP Error ID ltem Description 630601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Chec…

Error ID ltem Description
630301 Head Skip Communication Error
630302 Head Skip Head Origin
630303 Head Skip Overtime Head Origin Return
630304 Head Skip Unselected Nozzle Drop
630305 Head Skip Dummy Nozzle
630306 Head Skip Manual Bypass
630307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
630401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
630402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
630403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
630404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
630501 Master Head Offset Linear Measure System Was At High Position.
630502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-139 AIL01ETRP
3.3 Error IDs and Remedial Procedures

0511-002 2-140 AIL01ETRP
Error ID ltem Description
630601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
630701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
630702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
630801 Recog. Data Teach Recognition Error Code
630901 Trash Teach Error Code. Recognition Error Code
630b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures

(64 Master Head Offset)
Error ID ltem Description
640101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
640201 Nozzle Bypass Nozzle Down Error (L)
640202 Nozzle Bypass Nozzle Down Error (H)
640203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
640204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
640205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0511-003 2-141 AIL01ETRP
3.3 Error IDs and Remedial Procedures