4OM-1003-007 - 第352页

Error ID ltem Description 660601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Check if the master head is no…

100%1 / 409
Error ID ltem Description
660301 Head Skip Communication Error
660302 Head Skip Head Origin
660303 Head Skip Overtime Head Origin Return
660304 Head Skip Unselected Nozzle Drop
660305 Head Skip Dummy Nozzle
660306 Head Skip Manual Bypass
660307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
660401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
660402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
660403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
660404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
660501 Master Head Offset Linear Measure System Was At High Position.
660502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
3.3 Error IDs and Remedial Procedures
0305-001 2-151 AIL01ETRP
Error ID ltem Description
660601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
660701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
660702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
660801 Recog. Data Teach Recognition Error Code.
660901 Trash Teach Trash Teach Error Code.
660b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures
0511-002 2-152 AIL01ETRP
(67 Teaching Dust/Dirt Detection Diffusion Plate/Nozzle)
Error ID ltem Description
670101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
670201 Nozzle Bypass Nozzle Down Error (L)
670202 Nozzle Bypass Nozzle Down Error (H)
670203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
670204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
670205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
3.3 Error IDs and Remedial Procedures
0511-003 2-153 AIL01ETRP