4OM-1003-007 - 第359页
4.3 Recognition Error IDs and Remedial Procedures 4.3.1 Recognition Communication and Data Errors AA BB C DDDDD Detail Code Secondary Error Classification 1: Recognition Communication Data Range Error 2: Input Data Assem…

4.2 Recognition Error IDs and Controlled Areas
Basic System of Recognition Error IDs
A recognition error ID is expressed by 10 digits (decimal number) as
follows.
AA BB C DDDDD
Detailed Classification: Detail Code based on
Classification of Rec-
ognition Functions
Error Classification: Secondary Classifica-
tion Code of Detailed
Classification
Error Classification: Primary Classification
Code of Detailed Clas-
sification
Classification of Recognition Functions
Classification of Recognition Functions
Table 4B12
Recognition Error IDs Classification of Recognition Functions
01 Recognition Communication and Data
Check
02 Component Recognition Function
03 P.E.C. Recognition Function
04 Nozzle Recognition Function
10 Various Teaching Functions
13 Broken Circuit of Lamp for Component Rec-
ognition
14 Lighting Control Board-to-Board Communi-
cation
4.2 Recognition Error IDs and Controlled Areas
0305-001 2-170 AIL01ETRP

4.3 Recognition Error IDs and Remedial Procedures
4.3.1 Recognition Communication and Data Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
1: Recognition Communication
Data Range Error
2: Input Data Assembly Error
3: Input Data Error
Primary Error Classification
10 to 70: Recognition Communication Data Error
90: Recognition Communication Procedure Error
91: Recognition Communication Error
(Command Error)
92: Recognition Communication Error (Response Error)
Classification (01) of Recognition Functions
When an error ID other than the described ones is issued, contact
our service personnel for some advice.
Table 4B13
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0100100000 Error in Recognition Communication Data
(Cause) An error was found in the recognition communication data.
(Remedy 1) Contact our service personnel for details.
0121300000 "P.E.C. Lighting #2" is not Connected!
(Cause) Failed in confirmation to the connection of the lighting unit for ceramic boards.
(Remedy 1) Contact our service personnel for some advice.
0130300001 Error in "Camera MAGNIFICATION X or MAGNIFICATION Y" Data.
(Cause) Wrong parameters are set.
(Remedy 1) Set the correct data.
4.3 Recognition Error IDs and Remedial Procedures
0511-003 2-171 AIL01ETRP
Note

Recognition Error ID Recognition Error Contents, Cause, and Remedy
0131300001 Error in "Camera POSITION X or POSITION Y" Data.
0131300003 Error in "Camera ANGLE" Data.
0131300007 Error in "Camera 1 – 2 X or Y" Data.
0132300002 Error in "Camera GAIN or LEVEL" Data.
0133300001 Error in "Nozzle Offset High Mag. X or Y" Data.
0133300002 Error in "Nozzle Offset Low Mag. X or Y" Data.
0133300004 Error in "Nozzle O.D.Size" Data.
0133300005 Error in "Nozzle I.D.Size" Data.
0133300008 Error in "Nozzle V-Groove Size" Data.
0134300001 Error in "Individual Nozzle Gain or Level" Data.
0135300001 Error in "Nozzle High or Low level offset" Data.
0136300001 Error in "Nozzle Position Offset" Data.
0137300001 Error in "Head Center X or Y Offset" Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0511-002 2-172 AIL01ETRP