4OM-1003-007 - 第360页

Recognition Error ID Recognition Error Contents, Cause, and Remedy 0131300001 Error in "Camera POSITION X or POSITION Y" Data. 0131300003 Error in "Camera ANGLE" Data. 0131300007 Error in "Camera…

100%1 / 409
4.3 Recognition Error IDs and Remedial Procedures
4.3.1 Recognition Communication and Data Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
1: Recognition Communication
Data Range Error
2: Input Data Assembly Error
3: Input Data Error
Primary Error Classification
10 to 70: Recognition Communication Data Error
90: Recognition Communication Procedure Error
91: Recognition Communication Error
(Command Error)
92: Recognition Communication Error (Response Error)
Classification (01) of Recognition Functions
When an error ID other than the described ones is issued, contact
our service personnel for some advice.
Table 4B13
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0100100000 Error in Recognition Communication Data
(Cause) An error was found in the recognition communication data.
(Remedy 1) Contact our service personnel for details.
0121300000 "P.E.C. Lighting #2" is not Connected!
(Cause) Failed in confirmation to the connection of the lighting unit for ceramic boards.
(Remedy 1) Contact our service personnel for some advice.
0130300001 Error in "Camera MAGNIFICATION X or MAGNIFICATION Y" Data.
(Cause) Wrong parameters are set.
(Remedy 1) Set the correct data.
4.3 Recognition Error IDs and Remedial Procedures
0511-003 2-171 AIL01ETRP
Note
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0131300001 Error in "Camera POSITION X or POSITION Y" Data.
0131300003 Error in "Camera ANGLE" Data.
0131300007 Error in "Camera 1 – 2 X or Y" Data.
0132300002 Error in "Camera GAIN or LEVEL" Data.
0133300001 Error in "Nozzle Offset High Mag. X or Y" Data.
0133300002 Error in "Nozzle Offset Low Mag. X or Y" Data.
0133300004 Error in "Nozzle O.D.Size" Data.
0133300005 Error in "Nozzle I.D.Size" Data.
0133300008 Error in "Nozzle V-Groove Size" Data.
0134300001 Error in "Individual Nozzle Gain or Level" Data.
0135300001 Error in "Nozzle High or Low level offset" Data.
0136300001 Error in "Nozzle Position Offset" Data.
0137300001 Error in "Head Center X or Y Offset" Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0511-002 2-172 AIL01ETRP
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0138200000 Unavailable fiducial mark code was set.
0138200001 "Mark Size D2" is too big, compared with "D1".
0138200002 "Mark Size D3" is too big, compared with "D1".
0138200003 "Mark Size D2" is too big, comapred with"D3".
0138200004 "Window Size" is smaller than "Mark Size".
0138200005 "Mark Size D2" is not set.
0138200006 "Mark Size D3" is not set.
0138300001 Error in "P.C.B Recognition Mark Data Mark Size D1, D2 or D3" Data.
0138300003 Error in "P.C.B Recognition Mark Data Window Size" Data.
(Cause) Wrong parameters are set for the P.E.C. recognition function.
(Remedy) Refer to "Section 2 Pattern Program" in "Vol. 3" for details and set correct
parameters.
4.3 Recognition Error IDs and Remedial Procedures