4.3.3 P.E.C. Recognition Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (1 to 4)
Primary Error Classification (0 to 1)
Classification (03) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B16
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0300100000 Specified Mark Not Found in Recognizable Range.
0300200000 Unstable Image around Fiducial Mark.
0300300000 Extensive Error in Similitude of Mark Shape.
0300400000 Extensive Error in Similitude of Mark Shape or Size.
0301100000 Specified Mark Not Found in Recognizable Range.
(Cause 1)The fiducial mark and the fiducial mark coordinates X and Y or the mark
data are not suitable.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RETURN] button is pressed, the following recognition
window appears.
Fig. 4B26 Sample Display of Recognition Window
(Continue to the next page. )
0511-002 2-196 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note
(2) Manipulate the pointing device until the actual fiducial mark and
the template of the fiducial mark (located at the center of the
crosshair) overlap each other.
Note: Enlarge the view for accurate alignment operation. Other-
wise, components may not be placed accurately.
How to manipulate the pointing device
Move the actual fiducial mark with the joy stick.
Use the right button to enlarge the view.
Use the left button to reduce the view.
Fig. 4B27
(3) After adjusting the actual fiducial mark and the template accurately,
press the right and left buttons of the at the same time.
The "AUTO OPN." window resumes.
When the [START] button is pressed, the automatic operation starts
again.
Pressing both right and left buttons at the same time is vali-
dated only once.
If the actual fiducial mark and the template are not adjusted
correctly, components may not be placed accurately. In this
case, follow the remedial operation described below.
(3-1) Press the [STOP] button to stop the machine.
(3-2) Press the [Cancel] button to interrupt the automatic opera-
tion.
(3-3) Perform the zeroing operation on all axes.
(3-4) Open the "Run Mode" tab sheet. (Operation Sequence: [OPN.
MODE] Button Æ "Run Mode" Tab Sheet) Press the [SEMI-
AUTO (STEP)] button to re-start the automatic operation.
Fig. 4B28 Sample Display of Recognition Window
at Completion of Alignment Operation
0403-002 2-197 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note
4.3.4 Nozzle Recognition Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (1 to 4)
Primary Error Classification (0)
Classification (04) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B17
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0400100000 Nozzle Not Detected.
0400200000 Nozzle size has exceeded the allowable range.
0400300000 Nozzle position has exceeded the allowable range.
0400400000 Garbage and dirt are in a nozzle tip or a nozzle taper part.
(Cause 1) The nozzle is attached abnormally.
(Cause 2) The nozzle type data is abnormal.
(Remedy 1) Attach the nozzle correctly.
(Remedy 2) Check the nozzle type data. If necessary, correct it.