4OM-1003-007 - 第73页

1.3.2 Understanding of Maintenance Items on Each Section Clarified in this session are each individual spots of the machine to be maintained. Refer to "1.5 Maintenance Check List" for periodic maintenance. View…

100%1 / 409
1.3 Maintenance Spots
0305-001 1-9 AIL01ETRP
(15) Nozzle Change
Section
(14) Placement Change
Correction Section
(21) Placement
Up/Down Section
(11) Main Body
Driving Section
(9) Head Section
(5) Component
Receiving Box
(1) Air Source
(TCM-X300S)
(24) Head Up//Down Section
(25) Control Box
Section
(4) Component
Recognition Section
(23) Nozzle Guide Section
Fig. 4A6 Front View of Machine
Fig. 4A7 Rear View of Machine
(19) Pick-Up Up/Down
Section
(16) Nozzle Change/Return
Section
(12) Cutter Section
(1) Air Source
(TCM-X110J)
(10) Linear Measure
Detection Section
(6) Component Drop Prevantion Cover
1.3.2 Understanding of Maintenance Items on Each Section
Clarified in this session are each individual spots of the machine to be
maintained.
Refer to "1.5 Maintenance Check List" for periodic maintenance.
View of Inspection, Cleaning, and Lubrication Spots
(Example of Identification)
Fig. 4A9
*1: Maintenance Spot
*2: Cycle and Contents of Maintenance
*3: Details of Maintenance
*4: Maintenance Spot No.
These are used in "1.5 Maintenance Check List".
Display 1D2
Number (0, 1, 2 )
Cycle of Maintenance
1D: Every Day
1W:Every Week
1M: Every Month
3M: Every 3 Months
6M: Every 6 Months
1Y: Every Year
2
2
Main Air Pressure 1D2
Daily Inspection
Set Air Pressure 0.5 MPa (5.1 Kgf/cm )
Confirm that the air pressure is "Min. 0.4 MPa
(4.1 Kgf/cm )" while the machine is running.
If not, adjust the air pressure.
*1
*2
*3
*4
1.3 Maintenance Spots
0407-002 1-10 AIL01ETRP
1.3.3 Inspection, Cleaning, and Lubrication Spots
(1) Air Source
1.3 Maintenance Spots
0407-003 1-11 AIL01ETRP
Air Blowing Pressure 1D2
Daily Inspection
Confirm that the pressure gauge reads the initial
setting (0.05 to 0.08 MPa (0.5 to 0.8 kgf/cm ))
while the machine is running.
* Do not change the pressure unless necessary.
The pressure is factory-adjusted upon shipment
of the machine.
Drains 1W1
Weekly Cleaning
Drain the wastewater.
Note: Refer to "1.4 Maintenance Method"
for how to purge the drain.
Filters 3M1
Every 3 Months Cleaning
Detach the filters and clean them with an
air gun.
If a filter becomes defective, replace it with
a new one.
Note: Refer to "1.4 Maintenance Method"
Note: for how to detach the filter.
Main Air Pressure 1D1
Daily Inspection
Set Air Pressure 0.5 MPa (5.1 Kgf/cm )
Confirm that the air pressure is "Min. 0.4 MPa
(4.1 Kgf/cm )" while the machine is running.
If not, adjust the air pressure.
2
2
2
Subsidiary Air Pressure 1D3
Daily Inspection
Confirm that the subsidiary air pressure
is "0.29 MPa (3 kgf/cm
2
)" while the
machine is running.
If not, adjust the air pressure.
Fig. 4A10