Setup Center mit Setup Center Interface - 第21页
SIPLACE 3 Application program interface (API) description Ausgabe 05/2007 21 3.1.4 Architecture overview 3 Fig. 3.14 - 3 SCI architecture overview 3 3 3

3 Application program interface (API) description SIPLACE
Ausgabe 05/2007
20
3
3
3
3
3
3
3
3
3
3
3
3
3
Tape24mmX
Value: 280
Tape32mmX
Value: 288
Tape44mmX
Value: 300
Tape56mmX
Value: 312
Tape72mmX
Value: 328
Tape88mmX
Value: 344
TrayCarrier30
Value: 31
TrayCarrier51
Value: 32
TrayArbitraryCarrier
Value: 33
TrayWPC3
Value: 30
DipModul
Value: 20
RejectConveyor_ComponentExpress
Value: 50
TrayDDF2
Value: 250
TrayStackFeeder
Value: 1000006 (not yet defined unique in SSI, '250'
already exists)
TrayCarrier450
Value: 450
TrayMTC1
Value: 1000001 (not yet defined in SSI)
TrayMTC2
Value: 1000002 (not yet defined in SSI)
TrayWPC
Value: 1000003 (not yet defined in SSI)
TrayCarrierX
Value: 1000004 (not yet defined in SSI)
TrayArbitraryCarrierX
Value: 1000005 (not yet defined in SSI)

SIPLACE 3 Application program interface (API) description
Ausgabe 05/2007
21
3.1.4 Architecture overview
3
Fig. 3.14 - 3 SCI architecture overview
3
3
3
3 Application program interface (API) description SIPLACE
Ausgabe 05/2007
22
3.1.5 Restrictions
All restrictions described in the Version Description (item-no: 00195466-02) also concern this
SOKO. 3
3.1.5.1 Setup Center in general
This chapter describes restrictions concerning the whole Setup Center application. 3
– This interface is only compatible with SIPLACE X-series.
– This interface is only compatible with SIPLACE Pro 4.1, as Setup Center is bound to a specific
SPI version.
– For all used components, “verification” has to be activated in SIPLACE Pro.
– -The setting “Setup Verification System” of a used setup has to be set to “External … System”
in SIPLACE Pro.
– There has to be configured a line in Setup Center.
– Setup Center only works in unique ID mode, ICL mode is not supported by SCI. Therefore the
barcode definitions have to define a barcode with barcode fragment “UniqueId”.
– Table management has to be disabled.
– Splice monitoring has to be disabled.
– Quantity printout for ICL mode has to be disabled.
– Towers and carriers will be always set fully and always with one packaging unit. Each level has
to get an own packaging unique ID. Splice chains are not possible.
– -XML import has to be disabled.
3.1.5.2 Setup Center interface
This chapter describes restrictions concerning the whole functionality of the interface. 3
– The usage of SCI requires online verification.
– The SCI doesn’t support offline verification. Therefore the following methods and events only
concern online verification. From this follows, that docking station isn’t supported, too.
– New interface calls should only be executed, if Setup Center is in steady state. Disdain may
result in failures of command execution because Setup Center interacts with the machine,
which has a certain response time.
– -Splice chains have to be inserted into the interface always completely. If only one packaging
unit of an existing splice chain is used, the splice association will be deleted.
– The SCI doesn’t throw exceptions. Any exception, which occurs within Setup Center, will be
sent as string message.