Softwar e Module No Constant Name Classification Va l u e Unit Description 9 OPT_SIG_P ART_EMPTY Use 13 Const Combinations of the following setups are used. 1: Part Empty W arning (Y ellow/Blue) 2: Part Empty Error (Red)…

100%1 / 245
Software
1.4. System Constant
Module
No
Constant Name Classification
Value
Unit Description
21
System OPT_DOOR_OPEN Use 34 Const
D0-D3 : Front Door D4-D7 : Rear Door
>>0:No Check(NO) 1:Low Speed(LOW) 2:Emergency(EMER)
Value: Front, Rear
0 :NO, NO
1:LOW, NO
2:EMER, NO
16:NO, LOW
17:LOW, LOW
18:EMER, LOW
32:NO, EMER
33:LOW, EMER
34:EMER, EMER
19
MACHINE_NO Use Const Machine number setting.
Machine
20
Factory
MACHINE_TYPE Use 1 Const
Type of Machine
0 : The type without upward vision system.
1 : The type with upward vision system.
4
OPT_SIG_TYPE Use 0 Const Type of tower lamp (It is used by the MMI)
5
OPT_SIG_RED Use 2,112 Const Setting related to the operation of the tower lamp
6
OPT_SIG_YEL Use 257 Const
D0-D1: IDLE
D2-D3: RUN
D4-D5: PAUSE
7
OPT_SIG_GRN Use 292 Const
D6-D7: FREEZE
D8-D9: ADJUST
D10-D11: EMER
Tower Lamp
8
System
OPT_SIG_BLUE Use 0 Const
0: ACT_OFF
1 : ACT_ON
2 : ACT_BLINK
Software
Module
No
Constant Name Classification
Value
Unit Description
9
OPT_SIG_PART_EMPTY Use 13 Const
Combinations of the following setups are used.
1: Part Empty Warning (Yellow/Blue)
2: Part Empty Error (Red)
4: PCB Wait Warring (Yellow/Blue)
8: Bypass (Safe Guard) Warring (Yellow/Blue)
15
OPT_BUZONOFF Use 2 Const
0 : When an error occurs, the buzzer turns on always.
1 : When an error occurs, the buzzer turns off always.
2 : When an error occurs, the buzzer turns on selectively.
61
System
OPT_PCB_WAIT_WARNING_TIME
Use 20 sec
When waiting for the PCB in the Run state, the tower lamp signal is
changed after a given period of time (according to the setup of the
system Const #9).
10
OPT_IQ_FEEDER Use 0 Const
0 : The IT Feeder is not used.
1 : Use the front IT Feeder.
16 : Use the rear IT Feeder.
17 : Use the front and rear IT Feeder.
Feeder
20
System
OPT_FEED_OVER Use 34 Const
The Use fort the setting of the feeder unlock sensor.
>> D0-D3 : Front D4-D7 : Rear
0 : No Check(NO) 1 : Check(CH) 2 : INT Check(INT)
Value: Front, Rear
0 : NO, NO
1 : CH, NO
2 : CH-INT, NO
16 : NO, CH
17 : CH, CH
18 : CH-INT, CH
32 : NO, CH-INT
33 : CH, CH-INT
34 : CH-INT, CH-INT
Software
Module
No
Constant Name Classification
Value
Unit Description
22
OPT_TAPE_LINK Use 0 Const
Whether the Auto Link of the part supplied from a tape feeer is used or
not..
0: AUTO LINK
1: NOT LINK
23
OPT_STICK_LINK Use 0 Const
Whether the Auto Link of the part supplied from a stick feeder is used or
not..
0: AUTO LINK
1: NOT LINK
28
OPT_NO_FEEDER_CHG Use 0 Const
0: Feeder Change Button Use
1: Feeder Change No Use
59
OPT_TAPE_CLAMP Use 8 Const
0: Not Used.
1: Check for the tape feeder clamping when feeding the part.
2: Perform periodical check continuously.
4: Perform check when downloading the PCB.
8: Skip the feeder that is not clamped.
62
OPT_TAPE_INDEX Use 1 Const
0 : Do not perform check.
1 : Perform check at the time of feeding and generate the Emergency
error when
timeout occurs.
65
OPT_TAPE_LINK_OTHERSIDE Use 0 Const 0: Not Used , 1: Use
70
System
OPT_DUMPRATIO_IMPROVE Use 0 Const
0: Not use the feeder adjust function.
1: Use the feeder adjust function.
11
OPT_BADFIRST Use 0 Const
0 : Mark the fiducial mark first.
1: Mark the bad mark first.
Fiducial
69
System
OPT_MAN_MENU_DISABLE Use 0 Const
0:Normal
3: Disable the windows for the manual fiducial input function and retr
y
function.