SM411F_Service Manual - 第126页
Softwar e Module No Constant Name Classification Va l u e Unit Description 72 OPT_FID_DIST_CHK Use 0 Const 0: The function to check the distance between fiducials is not used. 1: Check the distance between fiducials and …

Software
Module
No
Constant Name Classification
Value
Unit Description
22
OPT_TAPE_LINK Use 0 Const
Whether the Auto Link of the part supplied from a tape feeer is used or
not..
0: AUTO LINK
1: NOT LINK
23
OPT_STICK_LINK Use 0 Const
Whether the Auto Link of the part supplied from a stick feeder is used or
not..
0: AUTO LINK
1: NOT LINK
28
OPT_NO_FEEDER_CHG Use 0 Const
0: Feeder Change Button Use
1: Feeder Change No Use
59
OPT_TAPE_CLAMP Use 8 Const
0: Not Used.
1: Check for the tape feeder clamping when feeding the part.
2: Perform periodical check continuously.
4: Perform check when downloading the PCB.
8: Skip the feeder that is not clamped.
62
OPT_TAPE_INDEX Use 1 Const
0 : Do not perform check.
1 : Perform check at the time of feeding and generate the Emergency
error when
timeout occurs.
65
OPT_TAPE_LINK_OTHERSIDE Use 0 Const 0: Not Used , 1: Use
70
System
OPT_DUMPRATIO_IMPROVE Use 0 Const
0: Not use the feeder adjust function.
1: Use the feeder adjust function.
11
OPT_BADFIRST Use 0 Const
0 : Mark the fiducial mark first.
1: Mark the bad mark first.
Fiducial
69
System
OPT_MAN_MENU_DISABLE Use 0 Const
0:Normal
3: Disable the windows for the manual fiducial input function and retr
y
function.

Software
Module
No
Constant Name Classification
Value
Unit Description
72
OPT_FID_DIST_CHK Use 0 Const
0: The function to check the distance between fiducials is not used.
1: Check the distance between fiducials and if it exceeds the allowable
value (1mm), an error occurs.
12
OPT_TRAYTIME Use 1 Const
0 : Change the pallet in basic mode, which is stable.
1 : Change the pallet quickly.
2 : Change the pallet quickly at the maximum speed.
16
OPT_TRAY_NONSTOP Use 0 Const
For determining whether to set the non-stop function of the FW12M/S
tray feeder. It must be set to 0 when using the non-stop function of
another model.
0 : Not Using the Tray Non Stop.
1 : Using
24
OPT_TRAY_LINK Use 0 Const
Whether the Auto Link of the tray part is used or not.
0: AUTO LINK
1: NOT LINK
Tray
68
System
OPT_NONSTOP_METHOD Use 0 Const
Master/Slave: 0
Master/Master: 1
1Slot Buffer: 2
13
OPT_AUTOSKIP Reserved 0 Const
When there is no part or an error occurred during operation, the function
is used to perform the skipped work after skipping the corresponding
placement on the PCB and finishing the work on the PCB.
0 : The auto skip function is not used.
1 : Use the auto skip function.
Option
25
System
OPT_HOME_METHOD Use 15 Const
1: Once the XY homin
g
is performed before actual placement, it is not
performed newly.
2: Once the Z homin
g
is performed before actual placement, it is not
performed newly.
4: Once the R homing is performed before actual placement, it is not
performed newly.
8: Once the MIR homin
g
is performed before actual placement, it is not
performed newly.
16: Once the BUT homin
g
is performed before actual placement, it is not
performed newly.

Software
Module
No
Constant Name Classification
Value
Unit Description
33
OPT_LTS_METHOD Use 0 Const
0: Not used.
1: Use.
41
OPT_LIGHT_SAVER_TIME_OUT Use 300 sec This function turns all lights off after the set time to protect the light.
57
System
OPT_AUTO_RUN_METHOD Use 0 Const
0: Not used
1: When starting the actual placement, perform the placement of the part
without waiting even though there is a PCB on the conveyor.
78
STOP_2_RUN_DELAY Use 1000 msec
The buzzer warnin
g
time when runnin
g
the machine a
g
ain after stoppin
g
it.
The alarm occurs for the given period of time.
79
Factory
STOP_2_RUN_METHOD Use 1 Const
The method to use the buzzer alarm when running the machine again
after stopping it. Add the value below.
0 : Not used.
1 : It is performed when dumping all parts and changing the feeder.
2 : It is performed when the machine is run in the pause status.
4 : It is performed when the machine is run in the SeqRestart mode.
8 : It is performed when the machine is run in the SeqRestart mode.
46
PCB_DOWN_VIS_MAKE Use 1 0, 1,2
It determines whether to start making vision immediately after
downloading the PCB file.
0 : Not Used.
1 : Starts making the vision and does not wait for the result.
2 : The next communication is available once the vision is made after
starting to make it.
48
Debug
SUPPORT_MMI_PANEL_BTN Use 0 0 , 1
0: Not supported by the MMI panel button.
1: Support MMI panel button.
Not Used
14
System
OPT_AUTOSRHRUN Reserved 0