Softwar e Module No Constant Name Classification Va l u e Unit Description 17 OPT_LARGE_PCB_SUPPORT Reserved 0 18 OPT_INLINE_TYPE Use 257 Const N-LINE Method D0-D7 : In D8-D15 : Out >> 0:Stand alone(ALONE), 1:Use B…

100%1 / 245
Software
Module
No
Constant Name Classification
Value
Unit Description
33
OPT_LTS_METHOD Use 0 Const
0: Not used.
1: Use.
41
OPT_LIGHT_SAVER_TIME_OUT Use 300 sec This function turns all lights off after the set time to protect the light.
57
System
OPT_AUTO_RUN_METHOD Use 0 Const
0: Not used
1: When starting the actual placement, perform the placement of the part
without waiting even though there is a PCB on the conveyor.
78
STOP_2_RUN_DELAY Use 1000 msec
The buzzer warnin
g
time when runnin
g
the machine a
g
ain after stoppin
g
it.
The alarm occurs for the given period of time.
79
Factory
STOP_2_RUN_METHOD Use 1 Const
The method to use the buzzer alarm when running the machine again
after stopping it. Add the value below.
0 : Not used.
1 : It is performed when dumping all parts and changing the feeder.
2 : It is performed when the machine is run in the pause status.
4 : It is performed when the machine is run in the SeqRestart mode.
8 : It is performed when the machine is run in the SeqRestart mode.
46
PCB_DOWN_VIS_MAKE Use 1 0, 1,2
It determines whether to start making vision immediately after
downloading the PCB file.
0 : Not Used.
1 : Starts making the vision and does not wait for the result.
2 : The next communication is available once the vision is made after
starting to make it.
48
Debug
SUPPORT_MMI_PANEL_BTN Use 0 0 , 1
0: Not supported by the MMI panel button.
1: Support MMI panel button.
Not Used
14
System
OPT_AUTOSRHRUN Reserved 0
Software
Module
No
Constant Name Classification
Value
Unit Description
17
OPT_LARGE_PCB_SUPPORT Reserved 0
18
OPT_INLINE_TYPE Use 257 Const
N-LINE Method
D0-D7 : In
D8-D15 : Out
>> 0:Stand alone(ALONE), 1:Use Busy(BUSY), 2:SMEMA
Previous machine, Next Machine
0:STAND,STAND
1:BUSY,STAND
2:SMEMA , STAND
256:STAND, BUSY
257:BUSY, BUSY
258:SMEMA, BUSY
512:STAND, SMEMA
513:BUSY, SMEMA
514:SMEMA, SMEMA
19
OPT_QUICKLOAD Use 17 Const
Registered when using the sensor for quick loading.
1: Quick Work->Use the Out Sensor
16: Sync Move (Quick Load)
26
OPT_QUICKLOAD_ETC Use 373 Const Other setup values related to the conveyor speed.
29
System
OPT_DISABLE_BUFFER Use 0 Const
0 : Use the In out buffer function.
1 : The In-buffer function is not used.
2 : The out-buffer function is not used.
3: The in-buffer and out-buffer function are not used.
Conveyor
15
Factory
TMV_PCB_LOCK_DELAY Use 100 msec
The delayed time until the PCB lock is sensed by a sensor.
It can be handled for each machine. (50-1000)
If the PCB moves after the fiducial is recognized, increase the value.
Software
Module
No
Constant Name Classification
Value
Unit Description
21
CONV_JOG_DIR Use 0 Const
0: Right Key + Dir,
1: Left Key + Dir
22
CONV_WIDTH_JOG_DIR Use 0 Const
0: Down Key + Dir
1: Up Key - Dir
23
CONV_FIX_TYPE Use 0 Const
0 : Standard of front side
1 : Standard of rear side
24
BOARD_FLOW_METHOD Use 0 Const
0 : Normal
1 : Back Return
27
CONV_1_TYPE Use 1 Const
Type of the conveyor
0: 1 stage Conveyor
1: 3 stage Conveyor
2: 3 stage motor conveyor
28
(CONV_2_TYPE) Reserved 0 - Not use.
29
CONV_1_AUTOWIDTH Use 1 Const
Whether the automatic width adjustment function is available or not.
0: Unavailable
1: Available.
30
(CONV_2_AUTOWIDTH) Reserved 0 - Not used.
31
BOARD_FLOW Use 0 Const
PCB transfer direction (PCB Flow)
0 : Left to right
1 : Right to Left
32
TMV_PCB_DELAY Use 300 msec
The time during which the PCB has been continuously pushed since
stopping by reducing the speed after the detection by the work sensor.
Push the PCB further to make it contact the placement stopper.
33
TMV_STP Use 3000 msec Timeout when operating the stopper related to the conveyor.
34
Factory
TMV_BUT Use 3000 msec Timeout when operating the BUT.