SM411F_Service Manual - 第136页

Softwar e Module No Constant Name Classification Va l u e Unit Description 98 IGNORE_BUTDOWN_SE NS OR Reserved 1 Const 0: There is BUT Down sensor . 0: There is no t BUT Down sensor . 49 Debug HEAD_LIGHT_BOARD_TYP E 0 0 …

100%1 / 245
Software
Module
No
Constant Name Classification
Value
Unit Description
34
SUPPORT_MOUNT_OPTI Use 1
Determine whether to use the placement option through which
the part is placed in a different order. (Pick , Align, Mount…)
0: Not used. 1: Use.
35
METHOD_MOUNT_OPTI Use 4
The option for the method to set the placement order.
51
USE_FLY_AUTOTEACH_RA
NGE
Use 0 0, 1
1: Use the value of FLY_AUTOTEACH_RANGE (#52) as
the recognition range when performing automatic teaching
(applicable only for fly camera).
0: Perform recognition on the entire screen.
52
FLY_AUTOTEACH_RANGE Use 0 um
Refer to No.51
60
SUPPORT_SMART_PROFIL
E
Use 95 const Supports smart profile algorism.
62
FLY_CONST_TIME Use 25 msec
Time to last the constant speed(XY speed) during
recognition by the fly camera.
63
FLY_DECSTART_TIME Use 90 msec
Time which the speed(XY speed) begin to be reduced
during recognition by the fly camera.
69
SUPPORT_SMART_SEQ Use 1 Const Supports the smart seq algorism.
16
READY_RELAY_DELAY Reserved 800 msec
The time delay from the time the Ready Relay is turned on
until it is checked.
0: Apply default value (approximately 150msec).
Others: According to the set value
17
USE_UPS Use 0 Const
0: UPS is not used.
1: Use the UPS.
H/W
18
Factory
CE_TYPE Use 0 Const
0: Not applied (the CE type).
1: Applied (the CE type)
Software
Module
No
Constant Name Classification
Value
Unit Description
98
IGNORE_BUTDOWN_SENS
OR
Reserved 1 Const
0: There is BUT Down sensor.
0: There is not BUT Down sensor.
49
Debug
HEAD_LIGHT_BOARD_TYP
E
0 0 , 1
0: Illumination board for the head for mass production.
1: Old illumination board
40
SYS_DELAY_XY1 Use 20 msec The delay that is used for general XY movement.
41
SYS_DELAY_XY2 Use 20 msec The delay that is used for XY movement for part pickup.
8 msec
The delay that is used for XY movement of placing the part
(Polling).
42
SYS_DELAY_XY3
Use 2 msec
The delay that is used for XY movement of placing the part
(Polling).
43
SYS_DELAY_XY4 Use 40 msec The delay that is used for high precision XY movement.
XY Move
44
Factory
SYS_BACKLASH_XY Use 5 um
The zone that is used in the XY backlash prevention
algorithm.
45
SYS_DELAY_Z1 Use 0 msec The delay that is used for general Z-axis movement.
46
SYS_DELAY_Z2 Reserved 0 msec -
47
SYS_DELAY_Z3 Reserved 0 msec -
48
SYS_DELAY_Z4 Use 20 msec The delay that is used for high precision Z movement.
49
SYS_BACKLASH_Z Reserved 0 um -
81
ESCAPE_Z_FAST Use 21000 um
The Z-axis position at which the part is picked up and the
mirror begins to close in the case of the FLY_SS Cycle
(6000 ~ 45000).
Z Move
82
Factory
ESCAPE_Z_MNT_FAST Use 2500 um
The Z-axis height to which the XY can move when the Z-
axis moves up after performing placement in the case of
the FLY_SS Cycle (1000 ~ 6000).
The values other than the above are treated as 8000.
Software
Module
No
Constant Name Classification
Value
Unit Description
50
SYS_DELAY_R1 Use 50 msec The delay that is used for general R-axis movement..
51
SYS_DELAY_R2 Use 50 msec The delay that is used for R-axis movement for part pickup.
52
SYS_DELAY_R3 Use 20 msec
The delay that is used for R-aix movement of placing the
part.
53
SYS_DELAY_R4 Use 50 msec The delay that is used for high precision R-axis movement..
54
SYS_BACKLASH_R Use 1500 mdeg
The zone that is used in the R-axis backlash prevention
algorithm.
83
Factory
HEAD_AUX_HOME Use 1 Const
Determine whether to use the auxiliary R-axis home sensor
of the head.
0: Not used 1: Used
R Move
26
Debug
R_MAX_SPEED_COMP_SIZ
E
Use 1,800 um
The part size that allows the R-axis to rotate at the
maximum speed.
Only for the part below 1800 based on the long side, R-aixs
moves at the maximum speed that can be obtained from
the SM411.
55
SYS_DELAY_M1 Use 0 msec
The delay when the mirror is closed in the case of the
FLY_SS Cycle.
56
SYS_DELAY_M2 Reserved 0 msec -
57
SYS_DELAY_M3 Reserved 0 msec -
58
SYS_DELAY_M4 Use 0 msec The delay when the mirror is closed.
59
Factory
SYS_BACKLASH_M Reserved 0 um -
Mir Move
80
Factory
ESCAPE_M_FAST Use 170000 mdeg
The Mirror-axis angle at which the Z-axis begins to move
when the mirror opens in the case of the FLY_SS Cycle
(80000 ~ 175000).
The values other than the above are treated as 80000.
60
HEAD_SIDE_DN_TIME Use 0 msec
The minimum period of time required to operate the side
illumination of the head.
Side Down
61
Factory
HEAD_SIDE_DN_TIMEOUT Use 500 msec Time out when operating the side illumination of the head.