SM411F_Service Manual - 第228页

Softwar e

100%1 / 245
SW & Control Part
Chapter 1. Software
SM400 S/W file structure
Path Contents
C:₩SmartSM
SmartSM)
- DBEditor.exe: mdb(DB) edit file
- ErrorMsg.mdb: Error Code and its
message Database file
- Range.mdb: Item별 Min/Max/Default
Value
Database file
5. After completing the change, check the input voltage by measuring it again.
6. The assembling is performed in the reverse order of disassembling.
Software
Software
Chapter 5. Motor Driver
5.1. Required Materials for Motor Driver
NO. PART NO. PART NAME Q’TY
TYPE REMARK
1 J3152016A
STEPPING MOTOR DRIVER
2
KR-55MF-2Z-3Z
2 J3153059A
SERVO MOTOR DRIVER-PB
2
PB1D003P101
3 J3153060A
SERVO MOTOR DRIVER-PB
4
PB1D002P101
4 J3153056A
SERVO MOTOR DRIVER(750W)
2
MCDDT3520
5 J3153054A
SM_DRIVER_50W
2
MADDT1205
6 J3153057A
SERVO MOTOR DRIVER(1KW)
4
MDDDT5540
5.2. Servo Motor Driver
5.2.1. Servo Motor Alarm Code
When an error occurs, the 7 segment LEDs of the motor drive will flicker. As well, the
corresponding alarm code is generated. It is of Err ** form and the ** will express the
corresponding alarm code.
In this case, take measures against the corresponding alarm code referring to the
following table.