SM411F_Service Manual - 第32页

Others - SM411F 23 (SM411F) -. For effectively blocki ng the droppin g components Chip Cover Cable protecting cover -. Tap is prepared fo r User Backup Block Back up table & etc Others - SM411F 24 (SM411F) Automatica…

100%1 / 245
Conveyor - SM411F
21
L510XW300Standard
Field OptionL510XW350Option 1
Factory Option
Option type
L610XW350
PCB
Option 2
Conveyor Option
Same coveyor system with SM421
(SM411F)
Others - SM411F
22
(SM411F)
Two pcs. of alarm lamp for conveniently telling
Operator can easily find out which side of the machine
has problem with shortage of components or minor
errors
Cover for Side Tray is standard
Others - SM411F
23
(SM411F)
-. For effectively blocking the dropping components
Chip Cover
Cable protecting cover
-. Tap is prepared for User Backup Block
Back up table & etc
Others - SM411F
24
(SM411F)
Automatically detecting Flux and injecting
Flux dipping device for POP process
H/W
Control block diagram
2
Layout of wiring harness
3
Improvement of workability
4
SM330 HW
Summary of machine
1
Composition of control rack and control board
5
25
[1] Summary of machine
1) Specification of SM411(F)(Utility)
- Input voltage : 3 phase, 200/208/220/240/380/415VAC, 50/60Hz
- Rating : 5.0KVA(max)
2) Specification of SM411(F)’s control part
- Controller : VME base motion controller
(X7043-TWIN SERVO B/D, X7043-STEP CONTROL B/D
X7043-SEDES B/D & SEDES SLAVE B/D )
- Motion axis (SM411-Total 40 axis, SM411F-33 axis)
1) XY table : Gantry 1 + Gantry 2 : 6 axis
2) Head assy. : Gantry 1 + Gantry 2 : 20 axis
3) Conveyor + Shuttle assy. : 14 axis(7 axis for SM411F)
26