SM411F_Service Manual - 第33页
H/W Control block diagram 2 Layout of wiring harne ss 3 Improvement of workability 4 SM330 HW Summary of machin e 1 Composition of control rack and control board 5 25 [1] Summary of machine 1) Specification of SM411(F)(U…

Others - SM411F
23
(SM411F)
-. For effectively blocking the dropping components
Chip Cover
Cable protecting cover
-. Tap is prepared for User Backup Block
Back up table & etc
Others - SM411F
24
(SM411F)
Automatically detecting Flux and injecting
Flux dipping device for POP process

H/W
Control block diagram
2
Layout of wiring harness
3
Improvement of workability
4
SM330 HW
Summary of machine
1
Composition of control rack and control board
5
25
[1] Summary of machine
1) Specification of SM411(F)(Utility)
- Input voltage : 3 phase, 200/208/220/240/380/415VAC, 50/60Hz
- Rating : 5.0KVA(max)
2) Specification of SM411(F)’s control part
- Controller : VME base motion controller
(X7043-TWIN SERVO B/D, X7043-STEP CONTROL B/D
X7043-SEDES B/D & SEDES SLAVE B/D )
- Motion axis (SM411-Total 40 axis, SM411F-33 axis)
1) XY table : Gantry 1 + Gantry 2 : 6 axis
2) Head assy. : Gantry 1 + Gantry 2 : 20 axis
3) Conveyor + Shuttle assy. : 14 axis(7 axis for SM411F)
26

[2] Control block diagram
27
[3-1] Layout of front wiring harness
DC power supply
(400W X 4EA)
24VDC
Driver of head’s R axis
(2EA)
Transformer
(5.0KVA)
PC-VME rack assy.
28