SM411F_Service Manual - 第48页
1.2.1. Axis Home Calibration Sets the limit position of each axis to move. When this button is clicked on, the following dialog box is displayed. Figur e 1- 1. “ System Axis Limit Info. ” dialogbox <Motor Select>…

1.2. Calibration [F9]
Used to perform calibrations related with the XY Gantry, Conveyor and camera.
The order in which the calibration is performed and the calibration tool needed to
perform the corresponding calibration is as follows;
Axis Home Calibration
Skew Compensation
Fiducail Camera Scale Calibration
Common X-Y (1
st
)
Conveyor Calibration
X-XY Compensation – Calibration Bar
Common X-Y (2
nd
)
Thermal Mapping
Gantry Mapping
ANC Fiducial Mark Teaching
Head & Camera Calibration - CN040, LightFly Nozzle, LightFly Nozzle,
CNT20
Board Position

1.2.1. Axis Home Calibration
Sets the limit position of each axis to move. When this button is clicked on, the
following dialog box is displayed.
Figure 1-1. “System Axis Limit Info.” dialogbox
<Motor Select> listbox
Select the motor axis for which to set the limit. Available axes are as follows.
G1F-X: X axis of the gantry1
G1F-Y: Y axis of the gantry1
G1R-X: X axis of the gantry2
G1R-Y: Y axis of the gantry2
H1F-Z1: Z axis of head1 of the gantry1
H1F-Z2: Z axis of head2 of the gantry1
H1F-Z3: Z axis of head3 of the gantry1
H1F-Z4: Z axis of head4 of the gantry1
H1F-Z5: Z axis of head5 of the gantry1
H1F-Z6: Z axis of head6 of the gantry1
H1F-M1: Mirror axis of the Gantry1
H1F-R1: Theta axis (H1, H2) of the Gantry1
H1F-R3: Theta axis (H3, H4) of the Gantry1
H1F-R5: Theta axis (H5, H6) of the Gantry1
H1R-Z1: Z axis of head1 of the Gantry2

H1R-Z2: Z axis of head2 of the Gantry2
H1R-Z3: Z axis of head3 of the Gantry2
H1R-Z4: Z axis of head4 of the Gantry2
H1R-Z5: Z axis of head5 of the Gantry2
H1R-Z6: Z axis of head6 of the Gantry2
H1R-M1: Mirror axis of the Gantry2
H1R-R1: Theta axis (H1, H2) of the Gantry2
H1R-R3: Theta axis (H3, H4) of the Gantry2
H1R-R5: Theta axis (H5, H6) of the Gantry2
ST1F-W: Width control motor of the work Station(F2)
<Software Limit> Group
<X-Y Axis Limit Automatic Searching…> button
Finds the limit of the X and Y axes automatically and checks whether to
apply the changed value.
<Skew Compensation> button
Activated when selecting the Y axis. It is used to perform the skew
compensation. For further details, refer to “1.2.2 Skew compensation”.
<Calibrate Home> button
Automatically finds and reflects the home position of the motor selected from
the <Motor Select> list box.
<CALIBRATE HOME ALL AXIS> button
Automatically finds and reflects the home positions of all axes.