2OM-1075-002.pdf - 第218页

AHB01ESPP 7.3.1.2 "PCB Lct Sol Adj" T ab Sheet This tab sheet enables the operator to activate the P .C.B. locate sole- noid. • • • • • Sheet Layout When the "PCB Lct Sol Adj" tab is pressed in the &q…

100%1 / 469
AHB01ESPP
[Transfer Out-Cnvr Buffer Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the P.C.B. is transferred to output
conveyor buffering position.
[PCB locate] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves up to the P.C.B.
locate position.
[PCB unlocate] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves down to its origin
position.
[Move B.P.C. to PCB Locate Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its positioning
section.
[Move B.P.C. to Standby Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its standby posi-
tion.
The standby position is specified in the current pattern pro-
gram.
[Zero B.P.C.] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its origin posi-
tion.
*2 "Control Sw" Group Box
When the [ENABLE] button on the operation panel is pressed in 2
seconds after one of the buttons in the "Operation" group box (*1) is
selected and the [ON] button (entitled "MOVE") is pressed, the ac-
tion corresponding to the selected button takes place.
Operation Procedure
(1) Set parameters in the "Xfr Prmtr Adj" tab sheet.
(2) Select one of the buttons in the "Operation" group box (*1).
(3) Press the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
7.3 "PCB Support Pins Set-up Mode" Tab
Note
0206-001 5-54-1
AHB01ESPP
7.3.1.2 "PCB Lct Sol Adj" Tab Sheet
This tab sheet enables the operator to activate the P.C.B. locate sole-
noid.
Sheet Layout
When the "PCB Lct Sol Adj" tab is pressed in the "Conveyor Adj" win-
dow, the following tab sheet appears.
Fig. 2E46 "PCB Lct Sol Adj" Tab Sheet
Sheet Composition
*1 "Operation" Group Box
The following buttons are provided in this group box.
Select one of the following buttons.
[Stopper] Button
When pressed, this button activates P.C.B. Stopper P1 or P2.
[Width near] Button
When pressed, this button narrows the conveyor width, using
the P.C.B. YL or YR pusher.
[Clamp] Button
When pressed, this button activates the P.C.B. ZL or ZR clamp.
7.3 "PCB Support Pins Set-up Mode" Tab
*1
*4
*2
*3
0206-002 5-55
AHB01ESPP
*2 "Up and Down Control" Group Box
The following buttons are provided in this group box.
The contents of the sheet differ, depending on the button selected in
the "Operation" group box (*1).
Unit Buttons
[Stopper] Button Selected : [P1], [P2]
[Width near] Button Selected : [YL], [YR]
[Clamp] Button Selected : [ZL], [ZR]
Control Buttons
[Stopper] Button Selected : [Upward] and [downward] Buttons
[Width near] Button Selected : [Clamp ON] and [Clamp OFF]
Buttons
[Clamp] Button Selected : [Clamp ON] and [Clamp OFF]
Buttons
*3 "Time" Group Box
When the [Stopper] button is selected in the "Operation" group box
(*1), the periods of time required for upward and downward move-
ment on the L and R sides.
When the [Width near] or the [Clamp] button is selected in
the "Operation" group box (*1), the "Time" group box (*3)
disappears.
*4 "Control Sw" Group Box
When the [ENABLE] button on the operation panel is pressed in 2
seconds after some buttons in "*1" and "*2" are selected and the
[ON] button (entitled "MOVE") is pressed, the action corresponding
to the selected buttons takes place.
Operation Procedure
(1) Select one of the buttons in the "Operation" group box (*1).
(2) Select one of the unit buttons and press the desired control button
in the "Up and Down Control" group box (*2).
(3) Press the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
7.3 "PCB Support Pins Set-up Mode" Tab
Note
0206-001 5-55-1