2OM-1075-002.pdf - 第270页
AHB01ESPP (4-4) When the [Manual] button is pressed in the "Feeder No. Set" sheet, the following edit window appears. Fig. 2F32 "Manual" Edit Window (4-5) Enter a feeder No., using the number keys (te…

AHB01ESPP
(4) Setting of Feeder No. for Tested Component
(4-1) When the [Fdr. No.] button (*5) is pressed in the "Component
Recog. Test" sheet (Fig. 2F22), the following "Fdr. No." sheet
appears.
Fig. 2F30 "Fdr. No." Sheet
(4-2) Press the [Front Ctr] or the [Rear Ctr] button in the "Fdr. No."
sheet.
(4-3) When the [Feeder No. Set] button is pressed in the "Fdr. No."
sheet, the "Feeder No. Set" sheet appears.
Fig. 2F31 "Feeder No. Set" Sheet
0206-003 6-37
3.3 "Cmpnt Recog Test" Tab

AHB01ESPP
(4-4) When the [Manual] button is pressed in the "Feeder No. Set"
sheet, the following edit window appears.
Fig. 2F32 "Manual" Edit Window
(4-5) Enter a feeder No., using the number keys (ten-key pad) and
press the [Set] button.
(4-6) When the [Cmpnt Data Lookup] button is pressed in the
"Feeder No. Set" sheet, the following "Component Data
Lookup Mode" sheet appears, making it possible to select a
feeder No. while checking the component allocation.
Fig. 2F33 "Component Data Lookup Mode" Sheet
(4-7) After specifying the desired feeder base, select the feeder
No. and press the [Set] button.
0206-003 6-38
3.3 "Cmpnt Recog Test" Tab

AHB01ESPP
(5) Setting of Carrier Movement Operation
(5-1) When the [Carrier Move] button (*9) is pressed in the "Com-
ponent Recog. Test" sheet (Fig. 2F22), the following "Carrier
Move" sheet appears.
Fig. 2F34 "Carrier Move" Sheet
(5-2) Press the [OFF] or the [ON] button.
3.3 "Cmpnt Recog Test" Tab
0206-003 6-39